| ¿µ¹® | intermittent positive pressure breathing(IPPB) | ÇÑ±Û | °£ÇæÀû¾ç¾ÐÈ£Èí |
|---|---|---|---|
| ¼³¸í | Æó¸¦ ÆØÃ¢½Ã۱â À§ÇÏ¿© ´ë±â¾Ðº¸´Ù ³ôÀº ¾Ð·ÂÀ» ÀÌ¿ëÇÏ´Â ÀΰøÈ£Èí¹ýÀÌ´Ù. ½Å»ý¾Æ ¹«±âÆóÀÇ Ä¡·á³ª ¸¸¼º Æó¼â¼º È£Èí±â ÁúȯÀÇ ±Þ¼º ¾ÇȽÃ, Áø´ÜÀ» À§ÇÑ °¡·¡ÀÇ ¹èÃâÀ» À§ÇÏ¿©, ¶Ç´Â ¾àÁ¦ÀÇ ÈíÀÔ¿¡ »ç¿ëÇϰí ÀÖ´Ù. ÇÕº´ÁõÀ¸·Î °ø±â°¡½¿ÁõÀ̳ª ½É¹ÚÃâ·®ÀÇ °¨¼Ò°¡ ¿Ã ¼ö ÀÖ´Ù. |
||
| ¿µ¹® | pulse pressure | ÇÑ±Û | ¸Æ¹Ú¾Ð |
|---|---|---|---|
| ¼³¸í | ¼öÃà±â Ç÷¾Ð°ú È®Àå±â Ç÷¾ÐÀÇ Â÷ÀÌ. mmHg·Î Ç¥½ÃÇÑ´Ù. ½ÉÀåÀÇ ¼öÃà·Â, µ¿¸Æ ³» Ç÷·ù·®, µ¿¸Æº®ÀÇ ±äÀåµµ¿¡ ¿µÇâÀ» ¹Þ´Â´Ù. Á¤»óÄ¡´Â ¼öÃà±â Ç÷¾ÐÀÇ 1/3, ¶Ç´Â È®Àå±â Ç÷¾ÐÀÇ 1/2ÀÌ´Ù. 60mmHgÀÌ»óÀ» ´ë¸ÆÀ̶ó°í Çϸç, ´ëµ¿¸ÆÆÇ¸· Æó¼âºÎÁ·Áõ, °©»ó»ùÇ×ÁøÁõ, µ¿¸Æ°æÈÁõ, Ç÷¾ÐÀÌ »ó½ÂÇÒ ¶§ ½ÉÀåºñ´ë, °í¿ µî¿¡¼ º¼ ¼ö ÀÖ´Ù. 20mmHg ÀÌÇϸ¦ ¼Ò¸ÆÀ̶ó°í Çϸç, ±Þ¼º ½É±Ù°æ»ö¿¡ ÀÇÇÑ ÁÂ½É½Ç ¼öÃà·Â ÀúÇÏ, ´ëµ¿¸ÆÆÇ¸· ÇùÂøµî¿¡¼ º¼ ¼ö ÀÖ´Ù. ÇÑÆí ¸Æ¾ÐÀÇ 1/3¿¡ È®Àå±â Ç÷¾ÐÀ» ´õÇÑ °ÍÀ» Æò±ÕÇ÷¾ÐÀ̶ó°í ÇÑ´Ù. |
||
| ¿µ¹® | osmotic pressure | ÇÑ±Û | »ïÅõ¾Ð |
|---|---|---|---|
| ¼³¸í | »ïÅõ¶ó´Â Çö»óÀº ÀÏÁ¤ Å©±â ÀÌÇÏÀÇ ¹°ÁúÀº Åë°ú½ÃŰ°í ±× ÀÌ»óÀÇ Å©±â¸¦ °¡Áø ¹°ÁúÀº Åë°ú ½ÃŰÁö ¸øÇÏ°Ô ÇÏ´Â ¸·(¹ÝÅõ¸·)À» »çÀÌ¿¡ µÎ°í ¾çÂÊ¿¡ ±× ¸·À» Åõ°úÇÏÁö ¸øÇÏ´Â ¹°ÁúÀÇ ³óµµ°¡ Â÷À̰¡ ³¯ ¶§ ¹ß»ýÇÏ´Â °ÍÀ¸·Î ¸·À» Åë°úÇÒ ¼ö ÀÖ´Â ¹°ÁúÀÌ ¸· ¾çÂÊÀÇ Åë°ú ÇÒ ¼ö ¾ø´Â ¹°ÁúÀÇ ³óµµ¸¦ °°°Ô ÇÏ´Â ¹æÇâÀ¸·Î ¿òÁ÷ÀÌ´Â °ÍÀ» ¸»ÇÑ´Ù. |
||
| ¿µ¹® | systolic pressure | ÇÑ±Û | ¼öÃà±â¾Ð |
|---|---|---|---|
| ¼³¸í | ½ÉȰµ¿·Â, µ¿¸Æº®ÀÇ Åº·Â¼º, Ç÷¾×·®, Ç÷¾×ÀÇ Á¡¼º µî¿¡ ÀÇÇÏ¿© °áÁ¤µÇ´Â Ç÷¾×ÀÇ µ¿¸Æº®¿¡ ¹ÌÄ¡´Â ¾Ð·ÂÀ¸·Î¼, ÃÖ°íÇ÷¾ÐÀº ¿Þ½É½Ç·ÎºÎÅÍ ¹ÚÃâÀÌ ³¡³ª±â Á÷Àü¿¡ »ý±â´Â ¾ÐÀ» ¸»Çϰí ÃÖ´ë Ç÷¾Ð ¶Ç´Â ¼öÃà±âÇ÷¾ÐÀ̶ó ºÎ¸¥´Ù. ÃÖ¼ÒÇ÷¾ÐÀº ¿Þ½É½ÇÀÇ È®ÀåÀÌ ³¡³ª´Â ½Ã±â¿¡ »ý±â´Â Ç÷¾ÐÀ» ¸»Çϸç ÃÖ¼ÒÇ÷¾Ð ¶Ç´Â È®Àå±âÇ÷¾ÐÀ̶ó°í ºÎ¸¥´Ù. Æò±ÕÇ÷¾ÐÀº µ¿¸Æ³»¾ÐÀÇ Æò±ÕÄ¡¸¦ ¸»Çϸç, ±âÃÊÇ÷¾ÐÀº Àý´ë¾ÈÁ¤ »óÅ¿¡¼ ÃøÁ¤ÇÑ Ç÷¾ÐÀ» ¸»ÇÑ´Ù. |
||
| ¿µ¹® | blood pressure | ÇÑ±Û | Ç÷¾Ð |
|---|---|---|---|
| ¼³¸í | Ç÷¾ÐÀ̶õ Ç÷°ü¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»ÇÏ´Â °ÍÀ¸·Î ´ë°³ Ưº°ÇÑ ¼³¸íÀÌ ¾øÀ¸¸é µ¿¸ÆÀÇ ¾Ð·ÂÀ» ¸»ÇÑ´Ù. Ç÷¾Ð¿¡´Â ¼öÃà±âÇ÷¾Ð(systolic blood pressure)°ú À̿ϱâÇ÷¾Ð(diastolic blood pressure)ÀÌ ÀÖ´Ù. ¼öÃà±âÇ÷¾ÐÀ̶õ ½ÉÀåÀÌ ¼öÃàÇÒ °æ¿ì¿¡ µ¿¸Æ¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»Çϰí, À̿ϱâ Ç÷¾ÐÀ̶õ ½ÉÀåÀÌ ÀÌ¿ÏÇÒ °æ¿ì¿¡ µ¿¸Æ¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»ÇÑ´Ù. ´ç¿¬È÷ ¼öÃà±â Ç÷¾ÐÀÌ À̿ϱâ Ç÷¾Ðº¸´Ù ³ô´Ù. Ç÷¾ÐÀ» ¸»ÇÒ ¶§¿¡ ¿¹¸¦ µé¾î 120/80mmHgÀ̶ó°í Àû´Â °ÍÀÇ ¾ÕÀÇ °ÍÀº ¼öÃà±â Ç÷¾ÐÀ» ÀǹÌÇÏ°í µÚ¿¡ Àû´Â 80Àº À̿ϱâ Ç÷¾ÐÀ» ÀǹÌÇÑ´Ù. |
||
| ECG | Electro-Cardio-Graphy(-Gram); ½ÉÀüµµ = EKG 1. Conducting System Structu... |
|---|---|
| NPBV | negative pressure body ventilator |
| NPV | negative predictive value; pressure value; negative pressure ventilation; net present value; nuclear... |
| VPM | ventilator pressure manometer; ventroposteromedial |
| PNP | pancreatic polypeptide; para-nitrophenol; peak negative pressure; pediatric nurse practitioner; peri... |
| VAP | Ventilator-associated pneumonia |
|---|---|
| VILI | ventilator-induced lung injury |
| LBNP | Lower Body Negative Pressure |
| NEP | Negative expiratory pressure |
| NPV | Negative pressure ventilation |
pressure necrosis
| ventilator | A ventilator is a machine which mechanically assists patients in the exchange of oxygen and carbon dioxide (sometimes referred to as artificial respiration). (12 Dec 1998) |
|---|---|
| ventilator weaning | Techniques for effecting the transition of the respiratory-failure patient from mechanical ventilation to spontaneous ventilation, while meeting the criteria that tidal volume be above a given threshold (greater than 5 ml/kg), respiratory frequency be below a given count (less than 30 breaths/min), and oxygen partial pressure be above a given threshold (pao2 greater than 50mm hg). Weaning studies focus on finding methods to monitor and predict the outcome of mechanical ventilator weaning as well as finding ventilatory support techniques which will facilitate successful weaning. Present methods include intermittent mandatory ventilation, intermittent positive pressure ventilation, and mandatory minute volume ventilation. (12 Dec 1998) |
| mechanical ventilator | <apparatus> Mechanically assisted breathing using a electrically powered device that forces oxygenated air into the lungs and then allow time for passive exhalation of air. (27 Sep 1997) |
| ventilators, negative-pressure | Body ventilators that assist ventilation by applying intermittent subatmospheric pressure around the thorax, abdomen, or airway and periodically expand the chest wall and inflate the lungs. They are relatively simple to operate and do not require tracheostomy. These devices include the tank ventilators ("iron lung"), portalung, pneumowrap, and chest cuirass ("tortoise shell"). (12 Dec 1998) |
| positive-negative pressure breathing | Inflation of the lungs with positive pressure and deflation with negative pressure by an automatic ventilator. (05 Mar 2000) |
| negative end-expiratory pressure | A subatmospheric pressure at the airway at the end of expiration. (05 Mar 2000) |
| negative pressure | Pressure less than that of the ambient atmosphere. (05 Mar 2000) |
| lower body negative pressure | External decompression applied to the lower body. It is used to study orthostatic intolerance and the effects of gravitation and acceleration, to produce simulated haemorrhage in physiologic research, to assess cardiovascular function, and to reduce abdominal stress during childbirth. (12 Dec 1998) |
| bone scan: falsely negative metastases | <radiology> Anaplastic tumours, reticulum cell sarcoma, renal cell carcinoma, thyroid carcinoma, histiocytosis, neuroblastoma, multiple myeloma (positive scan usually due to recent or impending fracture) (12 Dec 1998) |
| gram-negative | <microbiology> A common class of bacteria normally found in the gastrointestinal tract that can be responsible for disease in man (sepsis). Bacteria are considered to be gram-negative because of their characteristic staining properties under the microscope, where they either do not stain or are decolourised by alcohol during Gram's method of staining. This is a primary characteristic of bacteria that have a cell wall composed of a thin layer of peptidoglycan covered by an outer membrane of lipoprotein and lipopolysaccharide containing endotoxin. The gram staining characteristics of bacteria have resulted in an important classification system for the identification of bacteria. See: gram-positive (06 Oct 1997) |
| gram-negative aerobic bacteria | <microbiology> A large group of aerobic bacteria which show up as pink (negative) when treated by the gram-staining method. (12 Dec 1998) |
| gram-negative aerobic rods and cocci | <microbiology> A group of gram-negative bacteria consisting of rod- and coccus-shaped cells. They are both aerobic (able to grow under an air atmosphere) and microaerophilic (grow better in low concentrations of oxygen) under nitrogen-fixing conditions but, when supplied with a source of fixed nitrogen, they grow as aerobes. (12 Dec 1998) |
| gram-negative anaerobic bacteria | <microbiology> A large group of anaerobic bacteria which show up as pink (negative) when treated by the gram-staining method. (12 Dec 1998) |
| gram-negative anaerobic cocci | <microbiology> A group of anaerobic coccoid bacteria that show up as pink (negative) when treated by the gram-staining method. (12 Dec 1998) |
| gram-negative anaerobic straight, curved, and helical rods | <microbiology> A group of anaerobic, rod-shaped bacteria that show up as pink (negative) when treated by the gram-staining method. (12 Dec 1998) |
Á¦Ç°¸í |