| ¿µ¹® | carbon monoxide poisoning | ÇÑ±Û | ÀÏ»êÈź¼ÒÁßµ¶ |
|---|---|---|---|
| ¼³¸í | ÀÏ»êÈź¼ÒÀÇ ÈíÀÔ¿¡ ÀÇÇÏ¿© »êÈÇì¸ð±Û·ÎºóÀÌ Ä«¸£º¹½ÃÇì¸ð±Û·ÎºóÀ¸·Î º¯ÈÇÔÀ¸·Î½á ÀϾ´Â Áßµ¶. ÁßÃ߽Űæ°èÀå¾Ö¸¦ ÀÏÀ¸Å°°í Á×À½¿¡ À̸£±â°í ÇÑ´Ù. ÀÏ»êÈź¼Ò´Â ź¼Ò¸¦ ÇÔÀ¯ÇÑ À¯±â¹°ÀÌ ºÒ¿ÏÀü¿¬¼ÒÇÒ ¶§ ¹ß»ýÇÑ´Ù. µû¶ó¼ Á¦Ã¶, µµ½Ã°¡½º Á¦Á¶, °¡Á¤¿¡¼ ¹ß»ýÇϸç ÀÚµ¿Â÷ ¹è±â°¡½º¿¡µµ Æ÷ÇԵǾî ÀÖ°í °¡Á¤¿¡¼ ¿¬·áÀÇ ¿¬¼Ò¿¡ ÀÇÇØ¼µµ »ý±ä´Ù. ÀÏ»êÈź¼Ò¸¦ ÈíÀÔÇÏ¸é Æó¿¡¼ Ç÷¾×¼ÓÀÇ Ç÷»ö¼Ò¿Í °áÇÕÇÏ¿© ÀÏ»êÈź¼ÒÇì¸ð±Û·ÎºóÀ» Çü¼ºÇϰí, ÀÌ ¶§¹®¿¡ Ç÷¾×ÀÇ »ê¼Ò¿î¹Ý´É·ÂÀÌ »ó½ÇµÇ¾î ³»ºÎÀûÀÎ Áú½Ä»óÅ¿¡ ºüÁö°Ô µÈ´Ù. ÀÏ»êÈź¼Ò¿Í Çì¸ð±Û·Îºó°úÀÇ Ä£È¼ºÀº ±ØÈ÷ °ÇÏ¿© »ê¼Òº¸´Ù 250¹èÀÇ ¼¼±â·Î °áÇÕÇÑ´Ù. »ç¶÷¿¡ µû¶ó ÀÏ»êÈź¼Ò¿¡ ´ëÇÑ °¨¼ö¼ºÀÌ ´Ù¸£Áö¸¸, °ø±â ¼Ó¿¡ 0.001%¸¸ µé¾îÀ־ Áßµ¶À» ÀÏÀ¸Å²´Ù. ¶Ç 0.06%¿¡¼´Â 1½Ã°£¸¸ ÈíÀÔÇÏ¸é µÎÅëÀ» ÀÏÀ¸Å°°í 2½Ã°£ÀÌ¸é ½Ç½ÅÇÑ´Ù. ¶Ç 0.1%À» °æ¿ì´Â 1½Ã°£ À̳»¿¡ ½Ç½ÅÇϰí 4½Ã°£ÀÌ¸é »ç¸ÁÇÑ´Ù. Áßµ¶ Áõ¼¼´Â Á¶Á÷ÀÇ ¹«»ê¼ÒÁõ¿¡ ÀÇÇÑ °ÍÀ¸·Î¼, ±Þ¼ºÁßµ¶Àº ±Þ°ÝÈ÷ »ç¸ÁÇÏ´Â ¼öµµ ÀÖÁö¸¸, ´ë°³´Â óÀ½¿¡ µÎÅë-Çö±âÁõ-±Í¿ï¸²-±¸¿ª-±¸Åä µîÀÌ ÀÖ°í, »çÁöÀÇ ¿îµ¿ÀÌ ºÒ°¡´ÉÇÏ°Ô µÇ¸ç, ´Ù¼ÒÀÇ ÀǽÄÀÌ ³²¾Æ À־ ±×´ë·Î Á×À½¿¡ À̸£°Ô µÈ´Ù. Ÿ°¢ÀûÀ¸·Î´Â ¾ó±¼¿¡ È«Á¶¸¦ ¶ì°í Àü½Å¿¡ ¹«´Ì ¸ð¾çÀÇ ¹ßÀûÀÌ ³ªÅ¸³ª¸ç, È£ÈíÀÌ °¡´Ã°í ºÒ±ÔÄ¢ÇÏ°Ô µÈ´Ù. ÄÚ¸¦ °ñ°í ü¿ÂÀÌ ³»·Á°¡°í Àü½ÅÀÇ ±ÙÀ° À̿ µîÀÌ º¸À̸ç, È£Èí°ï¶õÀÇ Áõ¼¼°¡ º¸ÀÌÁö ¾Ê´Â Áß¿¡ È£ÈíÀÌ Á¤ÁöÇÏ°Ô µÈ´Ù. |
||
| LAMP | lysosome-associated membrane protein |
|---|---|
| SL | sarcolemma; sclerosing leukoencephalopathy; secondary leukemia; segment length; sensation level; sen... |
| SLE | slit lamp examination; St. Louis encephalitis; systemic lupus erythematosus |
| 'Greek letter alpha' | angular acceleration; first [carbon atom next to the carbon atom bearing the active group in organic... |
| beta [Greek letter beta] | an anomer of a carbohydrate; buffer capacity; carbon separated from a carboxyl by one other carbon i... |
| LAMP | Limbic system-associated membrane protein |
|---|---|
| LAMP | Lysosome-associated membrane protein |
| SLE | Slit lamp examination |
| FPDL | flash lamp-pumped pulsed dye laser |
| LAMP-1 | lysosome associated membrane protein |
| tungsten arc lamp | <apparatus> A lamp having highly compressed tungsten elements. (05 Mar 2000) |
|---|---|
| carbon-carbon double bond isomerases | <enzyme> Enzymes that catalyze the shifting of a carbon-carbon double bond from one position to another within the same molecule. Registry number: EC 5.3.3 (12 Dec 1998) |
| carbon-carbon ligases | <enzyme> Enzymes that catalyze the joining of two molecules by the formation of a carbon-carbon bond. These are the carboxylating enzymes and are mostly biotinyl-proteins. Registry number: EC 6.4 (12 Dec 1998) |
| carbon-carbon lyases | <enzyme> Enzymes that catalyze the cleavage of a carbon-carbon bond by means other than hydrolysis or oxidation. This subclass contains the decarboxylases, the aldehyde-lyases, and the oxo-acid-lyases. Registry number: EC 4.1 (12 Dec 1998) |
| annealing lamp | An alcohol lamp with a soot-free flame used in dentistry to drive off the protective NH3 gas coating from the surface of cohesive gold foil. (05 Mar 2000) |
| mercury vapor lamp | A lamp in which the electric arc is in an ionised mercury vapor atmosphere; it produces ultraviolet light that can be used therapeutically or in diagnostic photometry. (05 Mar 2000) |
| mignon lamp | A minute electric light used in various endoscopic instruments. (05 Mar 2000) |
| Wood's lamp | An ultraviolet lamp with a nickel oxide filter that only passes light with a maximal wavelength of about 3660 A |
| heat lamp | A lamp that emits infrared light and produces heat; used to apply topical heat to the skin. Synonym: thermolamp. (05 Mar 2000) |
| slit lamp | In ophthalmology, an instrument consisting of a combination of a microscope and a narrow beam of collimated light that can be narrowed into a slit and used to examine the eye. Synonym: biomicroscope, Gullstrand's slitlamp. (05 Mar 2000) Previous: slippery, slipping patella, slipping rib, slipping rib cartilage, slitNext: slit lamp, slit microscope, slit pores, slit-shellslit lamp <apparatus, ophthalmology> A special type of examination of the anterior structures of the eye. These include the conjunctiva, sclera, lids, iris, cornea and anterior chamber. The slit lamp is a device which focuses a high intensity light beam (that can be focused as a slit) at the structures of the eye while the examiner looks through a magnifying scope. Eyedrops which numb the eyes and dilate the pupils will often be used prior to examination. The exam is not at all uncomfortable, just time consuming. Diagnoses such as foreign body (to conjunctiva, cornea or sclera), iritis, herpes keratoconjunctivitis, cornmeal ulcer, cataracts, glaucoma and corneal abrasions may be made using this exam. Some foreign bodies can even be removed using the enhanced image amplification of the slit lamp. (19 Jan 1998) |
| spirit lamp | A lamp, used mainly for heating in laboratory work, in which alcohol is burned. (05 Mar 2000) |
| Edridge-Green lamp | A lantern used to test recognition of coloured signals; it displays a single light with colour filters in rotating disks that can be modified to simulate conditions of weather and atmosphere. This test for colour blindness was officially adopted in Great Britain in 1915 in place of the Holmgren wool test, but is now seldom used. (05 Mar 2000) |
| ultraviolet lamp | A lamp that emits rays in the ultraviolet band of the spectrum. See: ultraviolet. (05 Mar 2000) |
| Kromayer's lamp | A U-shaped quartz lamp of mercury vapor, giving out actinic rays; used in the treatment of skin diseases. (05 Mar 2000) |
| uviol lamp |
| carbon arc lamp |
has carbon electrodes
Ãâó: wordnet.princeton.edu/perl/webwn
|
|---|---|
| carbon arc lamp |
An arc lamp is a device that produces light by the sparking (or arcing, from voltaic arc or electric arc) of a high current between two carbon rod electrodes. The rods are touched and then slowly drawn apart; as the rods separate the current is "struck" and arcs across the gap in a bright, ionized path. The arc produces a temperature of several thousand degrees, and the tips of the carbon rods are heated to incandescence, creating light. ...
Ãâó: en.wikipedia.org/wiki/Carbon_arc_lamp
|
| carbon arc lamp | has carbon electrodes |
|---|
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|