| ¿µ¹® | blood pressure | ÇÑ±Û | Ç÷¾Ð |
|---|---|---|---|
| ¼³¸í | Ç÷¾ÐÀ̶õ Ç÷°ü¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»ÇÏ´Â °ÍÀ¸·Î ´ë°³ Ưº°ÇÑ ¼³¸íÀÌ ¾øÀ¸¸é µ¿¸ÆÀÇ ¾Ð·ÂÀ» ¸»ÇÑ´Ù. Ç÷¾Ð¿¡´Â ¼öÃà±âÇ÷¾Ð(systolic blood pressure)°ú À̿ϱâÇ÷¾Ð(diastolic blood pressure)ÀÌ ÀÖ´Ù. ¼öÃà±âÇ÷¾ÐÀ̶õ ½ÉÀåÀÌ ¼öÃàÇÒ °æ¿ì¿¡ µ¿¸Æ¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»Çϰí, À̿ϱâ Ç÷¾ÐÀ̶õ ½ÉÀåÀÌ ÀÌ¿ÏÇÒ °æ¿ì¿¡ µ¿¸Æ¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»ÇÑ´Ù. ´ç¿¬È÷ ¼öÃà±â Ç÷¾ÐÀÌ À̿ϱâ Ç÷¾Ðº¸´Ù ³ô´Ù. Ç÷¾ÐÀ» ¸»ÇÒ ¶§¿¡ ¿¹¸¦ µé¾î 120/80mmHgÀ̶ó°í Àû´Â °ÍÀÇ ¾ÕÀÇ °ÍÀº ¼öÃà±â Ç÷¾ÐÀ» ÀǹÌÇÏ°í µÚ¿¡ Àû´Â 80Àº À̿ϱâ Ç÷¾ÐÀ» ÀǹÌÇÑ´Ù. |
||
| ¿µ¹® | fetal monitoring | ÇÑ±Û | žư¨½Ã |
|---|---|---|---|
| ¼³¸í | ÀӽŠÁßÀ̳ª ºÐ¸¸ ÁßÀÇ Å¾ÆÀÇ »óŸ¦ ¾Ë¾Æº¸´Â °ÍÀ» žư¨½Ã¶ó°í ÇÑ´Ù. ¿©±â¿¡´Â ¿©·¯ °¡Áö ¹æ¹ýÀÌ Àִµ¥ Å©°Ô ºÐ¸¸Àü žư¨½Ã¿Í ºÐ¸¸Áß Å¾ư¨½Ã·Î Å©°Ô ³ª´«´Ù. 1. ºÐ¸¸Àü žư¨½Ã´Â ºÐ¸¸Çϱâ ÀÌÀüÀÇ Å¾ÆÀÇ »óŸ¦ °Ë»çÇÏ´Â ¹æ¹ýÀ¸·Î ´ÙÀ½°ú °°Àº ¿©·¯ °¡Áö ¹æ¹ýÀÌ ÀÖ´Ù. 1)¾ç¼öõÀÚ-ÁÖ»ç±â¸¦ ÀÌ¿ëÇØ¼ »ê¸ðÀÇ ¹è¸¦ ÅëÇØ¼ ¾ç¼ö¸¦ ¾ò¾î¼ ºÐ¼®ÇÏ¿© žÆÀÇ »óŸ¦ ¾Ë¾Æº¸´Â ¹æ¹ý. ÀӽŠ15ÁÖ À̻󿡼 ½Ç½ÃÇÒ ¼ö°¡ ÀÖ´Ù. 2)ÅÈÁÙõÀÚ-ÃÊÀ½ÆÄ°Ë»ç¸¦ ½Ç½ÃÇÏ¿© ¿µ»óÀ» º¸¸é¼ ÅÈÁÙ¼Ó¿¡ ¹Ù´ÃÀ» ³Ö¾î¼ ±×°÷ÀÇ Ç÷°üÀ» ã¾Æ Ç÷¾×À» äÃëÇÏ¿© °Ë»çÇÏ´Â ¹æ¹ý. 3)½ºÆ®·¹½º°Ë»ç-žƵµ Àڱüӿ¡¼ ¿îµ¿À» ÇÑ´Ù. ±×¸®°í Á¤»óÀûÀ¸·Î žư¡ Àڱüӿ¡¼ ¿îµ¿À» ÇÒ °æ¿ì¿¡´Â žÆÀÇ ½ÉÀå ¹Úµ¿ÀÌ »¡¶óÁö°Ô µÈ´Ù. žÆÀÇ ¿îµ¿°ú žÆÀÇ ½ÉÀå¹Úµ¿À» µ¿½Ã¿¡ °¨½ÃÇÏ¿© ¿îµ¿½Ã¿¡ žÆÀÇ ½ÉÀå¹Úµ¿ÀÌ »¡¶óÁö´Â °¡¸¦ ¾Ë¾Æº¸´Â °ÍÀÌ´Ù. 4)žÆÃ»°¢Àڱذ˻ç-30ÁÖ ÀÌ»óÀÌ µÈ žƴ ¼Ò¸®ÀÇ Àڱؿ¡ ´ëÇØ¼ ¹ÝÀÀÀ» ÇÑ´Ù. Áï ¼Ò¸®¸¦ µé·ÁÁÖ¾úÀ» °æ¿ì¿¡ žư¡ ¹ÝÀÀÀ» ÇØ¼ ½ÉÀåÀÇ ¹Úµ¿¼ö°¡ Áõ°¡¸¦ ÇÑ´Ù. 5)¼öÃེƮ·¹½º°Ë»ç-Á¤»óÀûÀΠžƴ ÀÚ±ÃÀÌ ¼öÃàÇϸé ÀÌ¿¡ ¹ÝÀÀÀ» ÇØ¼ ½É¹Ú¼ö°¡ º¯ÈÇÑ´Ù. À̰ÍÀ» ÀÌ¿ëÇÏ¿© žÆÀÇ »óŸ¦ °Ë»çÇÏ´Â ¹æ¹ýÀÌ´Ù. 2. ºÐ¸¸Áß Å¾ư¨½Ã ºÐ¸¸µµÁß¿¡ žÆÀÇ °Ç°»óŸ¦ °¨½ÃÇÏ´Â °ÍÀÌ´Ù. ´ëü·Î ºÐ¸¸µµÁß¿¡ žư¡ Àú»ê¼ÒÁõÀ̳ª ¿©·¯ °¡Áö Ãæ°ÝÀ» ¹Þ´Â °æ¿ì°¡ ¸¹À¸¹Ç·Î ºÐ¸¸µµÁßÀÇ Å¾ư¨½Ã´Â Áß¿äÇÑ Àǹ̸¦ °¡Áø´Ù. 1)ÀüÀڽĞư¨½Ã-Àü±âÀû ÀåÄ¡¸¦ ÀÌ¿ëÇÏ¿© žÆÀÇ »óŸ¦ ¾Ë¾Æº¸´Â °ÍÀ¸·Î °¨½ÃÀÇ ´ë»óÀº ÀÚ±ÃÀÇ ¼öÃà°ú žÆÀÇ ½ÉÀå¹Úµ¿¼öÀÌ´Ù. 2)žƸӸ®µ¤°³ Ç¥º»Ã¤Ãë Ç÷¾×-ºÐ¸¸µµÁß¿¡ žÆÀÇ µÎÇÇÀÇ Ç÷°ü¿¡¼ Ç÷¾×À» äÃëÇÏ¿© °Ë»ç¸¦ ÅëÇØ¼ žÆÀÇ »óŸ¦ ¾Æ´Â ¹æ¹ýÀÌ´Ù. ÁÖ·Î °Ë»ç¸¦ ÇàÇÏ´Â Á¾¸ñÀº Ç÷¾×ÀÇ pHÀÌ´Ù. |
||
| ¿µ¹® | blood clotting, blood coagulation | ÇÑ±Û | Ç÷¾×ÀÀ°í |
|---|---|---|---|
| ¼³¸í | »ç¶÷ÀÇ ¸ö¿¡ »óó°¡ ³ª¼ ÃâÇ÷ÀÌ ÀÖÀ» °æ¿ì¿¡ À̰ÍÀ» ¸·°í ÇǸ¦ ´õÀÌ»ó ³ªÁö ¾Ê°Ô ÇÏ´Â °ÍÀ» ÁöÇ÷À̶ó°í ÇÑ´Ù. ÁöÇ÷ÀÇ °úÁ¤¿¡´Â Å©°Ô µÎ °¡Áö ´Ü°è°¡ ÀÖ´Ù. ù¹øÂ° ´Ü°è´Â Ç÷¼ÒÆÇµéÀÌ »óó°¡ ³ª¼ ¼Õ»óµÈ Ç÷°üÀÇ ºÎÀ§¸¦ ¸·´Â °ÍÀÌ´Ù. ÀÌ·¸°Ô ÇÏ¸é ¿ì¼± Ç÷°üÀÇ ¼Õ»óºÎÀ§·Î ºÎÅÍ Çǰ¡ ³ª¿À´Â °ÍÀ» ¸·À» ¼ö°¡ ÀÖ´Ù. ´ÙÀ½ÀÇ ´Ü°è´Â »óó¸¦ ¸·°í ÀÖ´Â Ç÷¼ÒÆÇÀ§¿¡ ¿©·¯ °¡Áö ¹°ÁúµéÀÌ ÀÛ¿ëÇØ¼ ´õ¿í ´Ü´ÜÇÏ°Ô ÇÏ¿© »óó°¡ ³ Ç÷°ü¿¡¼ Çǰ¡ »õ´Â °ÍÀ» ¿µ±¸È÷ ¸·´Â °ÍÀÌ´Ù. ½±°Ô ¸»Çϸé Ç÷¼ÒÆÇÀº º®µ¹¿¡ ÇØ´çÇÏ´Â °ÍÀÌ°í µÎ¹øÂ° °úÁ¤¿¡ Âü¿©ÇÏ´Â ¹°ÁúµéÀº ½Ã¸àÆ®¿¡ ÇØ´çÇÏ´Â °ÍÀÌ´Ù. ÀÌ µÎ °úÁ¤ÀÌ ¿ÏÀüÇÒ °æ¿ì¿¡ ÁöÇ÷ÀÌ ¼øÁ¶·Ó°Ô ÀϾÙ. Ç÷¾×ÀÀ°í¶õ µÎ¹øÂ° ´Ü°è¸¦ ÁöĪÇÏ´Â ¸»·Î½á ¸Å¿ì º¹ÀâÇÑ ´Ü°è¸¦ °ÅÄ¡´Â ¹ÝÀÀÀ¸·Î ¸¶Áö¸· ´Ü°è´Â ¼¶À¯¼Ò¶ó´Â ¹°ÁúÀÌ ¸¸µé¾îÁ®¼ ÀÌ ¹°ÁúÀÌ Ç÷¼ÒÆÇ°ú ±× ¿ÜÀÇ ¼¼Æ÷¸¦ ´Ü´ÜÇÏ°Ô °íÁ¤½ÃÄÑ Çǰ¡ »óó³ Ç÷°üÀ¸·Î »õ´Â °ÍÀ» ¸·´Â´Ù. À̰ÍÀ» °¡Àå °£´ÜÈ÷ ¼³¸íÇÏÀÚ¸é Å©°Ô ´ÙÀ½°ú °°Àº 3°¡Áö ´Ü°è·Î ÀÌ·ç¾îÁø´Ù. ù¹øÂ° ´Ü°è´Â Ç÷°ü¼Õ»ó¿¡ ÀÇÇØ¼ ÇÁ·ÎÆ®·Òºó Ȱ¼ºÁ¦¶ó´Â °ÍÀÌ ¸¸µé¾îÁö´Â ´Ü°èÀÌ´Ù. µÎ¹øÂ° ´Ü°è´Â ÀÌ ÇÁ·ÎÆ®·Òºó Ȱ¼ºÁ¦¶ó´Â ¹°Áú¿¡ ÀÇÇØ¼ Ç÷¾×¼Ó¿¡ ÀÖ´Â ÇÁ·ÎÆ®·ÒºóÀ̶ó´Â ¹°ÁúÀÌ Æ®·ÒºóÀ̶ó´Â ¹°Áú·Î ¹Ù²î´Â ´Ü°èÀÌ´Ù. ¼¼¹øÂ° ´Ü°è´Â Æ®·ÒºóÀ̶ó´Â ¹°Áú¿¡ ÀÇÇØ¼ ¼¶À¯¼Ò¿øÀ̶ó´Â ¹°ÁúÀÌ ¼¶À¯¼ÒÀ¸·Î ¹Ù²î´Â ´Ü°èÀÌ´Ù. |
||
| ¿µ¹® | intermittent positive pressure breathing(IPPB) | ÇÑ±Û | °£ÇæÀû¾ç¾ÐÈ£Èí |
|---|---|---|---|
| ¼³¸í | Æó¸¦ ÆØÃ¢½Ã۱â À§ÇÏ¿© ´ë±â¾Ðº¸´Ù ³ôÀº ¾Ð·ÂÀ» ÀÌ¿ëÇÏ´Â ÀΰøÈ£Èí¹ýÀÌ´Ù. ½Å»ý¾Æ ¹«±âÆóÀÇ Ä¡·á³ª ¸¸¼º Æó¼â¼º È£Èí±â ÁúȯÀÇ ±Þ¼º ¾ÇȽÃ, Áø´ÜÀ» À§ÇÑ °¡·¡ÀÇ ¹èÃâÀ» À§ÇÏ¿©, ¶Ç´Â ¾àÁ¦ÀÇ ÈíÀÔ¿¡ »ç¿ëÇϰí ÀÖ´Ù. ÇÕº´ÁõÀ¸·Î °ø±â°¡½¿ÁõÀ̳ª ½É¹ÚÃâ·®ÀÇ °¨¼Ò°¡ ¿Ã ¼ö ÀÖ´Ù. |
||
| ¿µ¹® | pulse pressure | ÇÑ±Û | ¸Æ¹Ú¾Ð |
|---|---|---|---|
| ¼³¸í | ¼öÃà±â Ç÷¾Ð°ú È®Àå±â Ç÷¾ÐÀÇ Â÷ÀÌ. mmHg·Î Ç¥½ÃÇÑ´Ù. ½ÉÀåÀÇ ¼öÃà·Â, µ¿¸Æ ³» Ç÷·ù·®, µ¿¸Æº®ÀÇ ±äÀåµµ¿¡ ¿µÇâÀ» ¹Þ´Â´Ù. Á¤»óÄ¡´Â ¼öÃà±â Ç÷¾ÐÀÇ 1/3, ¶Ç´Â È®Àå±â Ç÷¾ÐÀÇ 1/2ÀÌ´Ù. 60mmHgÀÌ»óÀ» ´ë¸ÆÀ̶ó°í Çϸç, ´ëµ¿¸ÆÆÇ¸· Æó¼âºÎÁ·Áõ, °©»ó»ùÇ×ÁøÁõ, µ¿¸Æ°æÈÁõ, Ç÷¾ÐÀÌ »ó½ÂÇÒ ¶§ ½ÉÀåºñ´ë, °í¿ µî¿¡¼ º¼ ¼ö ÀÖ´Ù. 20mmHg ÀÌÇϸ¦ ¼Ò¸ÆÀ̶ó°í Çϸç, ±Þ¼º ½É±Ù°æ»ö¿¡ ÀÇÇÑ ÁÂ½É½Ç ¼öÃà·Â ÀúÇÏ, ´ëµ¿¸ÆÆÇ¸· ÇùÂøµî¿¡¼ º¼ ¼ö ÀÖ´Ù. ÇÑÆí ¸Æ¾ÐÀÇ 1/3¿¡ È®Àå±â Ç÷¾ÐÀ» ´õÇÑ °ÍÀ» Æò±ÕÇ÷¾ÐÀ̶ó°í ÇÑ´Ù. |
||
| CBV | capillary blood cell velocity; catheter balloon valvuloplasty; central blood volume; cerebral blood ... |
|---|---|
| NIBP | noninvasive blood pressure [monitoring] |
| CBF | capillary blood flow; cerebral blood flow; ciliary beat frequency; coronary blood flow; cortical blo... |
| HBF | hand blood flow; hemispheric blood flow; hemoglobinuric bilious fever; hepatic blood flow; hypothala... |
| ABP | actin-binding protein; ambulatory blood pressure; American Board of Pedodontics; American Board of P... |
| ABPM | Ambulatory Blood Pressure Monitoring |
|---|---|
| HBGM | Home Blood Glucose Monitoring |
| SMBG | Self-monitoring of blood glucose |
| ABPM | Ambulatory BP monitoring |
| AEM | Ambulatory Electrocardiographic Monitoring |
pressure necrosis
low blood pressure
| blood pressure monitoring, ambulatory | Method in which prolonged blood pressure readings are made while the patient undergoes normal daily activities. It allows quantitative analysis of the high blood pressure load over time, can help distinguish between types of hypertension, and can assess the effectiveness of antihypertensive therapy. (12 Dec 1998) |
|---|---|
| intraocular pressure monitoring | <ophthalmology, technique> This is procedure which measures the pressure inside the eyes. This is a screening test for glaucoma. This test is performed by an ophthalmologist. (27 Sep 1997) |
| blood gas monitoring, transcutaneous | The noninvasive measurement or determination of the partial pressure (tension) of oxygen and/or carbon dioxide locally in the capillaries of a tissue by the application to the skin of a special set of electrodes. These electrodes contain photoelectric sensors capable of picking up the specific wavelengths of radiation emitted by oxygenated versus reduced haemoglobin. (12 Dec 1998) |
| blood glucose monitoring | A way of testing how much glucose (sugar) is in the blood. A drop of blood, usually taken from the fingertip, is placed on the end of a specially coated strip, called a testing strip. The strip has a chemical on it that makes it change colour according to how much glucose is in the blood. A person can tell if the level of glucose is low, high, or normal in one of two ways. The first is by comparing the colour on the end of the strip to a colour chart that is printed on the side of the test strip container. The second is by inserting the strip into a small machine, called a meter, which reads the strip and shows the level of blood glucose in a digital window display. Blood testing is more accurate than urine testing in monitoring blood glucose levels because it shows what the current level of glucose is, rather than what the level was an hour or so previously. (09 Oct 1997) |
| blood glucose self-monitoring | Self evaluation of whole blood glucose levels outside the clinical laboratory. A digital or battery-operated reflectance meter may be used. It has wide application in controlling unstable insulin-dependent diabetes. (12 Dec 1998) |
| blood pressure | <cardiology, physiology> The force that the circulating blood exerts on the walls of the arteries. This measurement is divided into systolic (pressure during contraction of the heart) and diastolic (pressure during relaxation phase). Blood pressure varies with age and sex of the individual. A rough rule of thumb for normal systolic pressure is 100 + Age of individual. In children 2 x (age) + 80 = systolic BP The diastolic pressure should be roughly 2/3 the systolic pressure. (27 Sep 1997) |
| blood pressure determination | Techniques for measuring blood pressure. (12 Dec 1998) |
| blood pressure, high | High blood pressure (hypertension) is a repeatedly elevated blood pressure exceeding 140 over 90 mmHg. High blood pressure is also called the silent killer. Chronically high blood pressure can cause blood vessel changes in the back of the eye (retina), thickening of the heart muscle, kidney failure, and brain damage. No specific cause for high blood pressure is found in 95% of patients. High blood pressure is treated with salt restriction, regular aerobic exercise, and medications. (12 Dec 1998) |
| blood pressure monitors | Devices for continuously measuring and displaying the arterial blood pressure. (12 Dec 1998) |
| high blood pressure | <cardiology> Persistently high arterial blood pressure. Hypertension may have no known cause (essential or idiopathic hypertension) or be associated with other primary diseases (secondary hypertension). This condition is considered a risk factor for the development of heart disease, peripheral vascular disease, stroke and kidney disease. (29 Sep 1997) |
| systolic blood pressure | <cardiology, physiology> The pressure exerted on the walls of the arteries during the contraction phase of the heart. Considered abnormally elevated if consistently over 150 mmHg. Systolic blood pressure varies with age, sex, size and relative condition. (27 Sep 1997) |
| diastolic blood pressure | The pressure exerted on the walls of the arteries when the heart is in the relaxation phase (diastole). Considered abnormally elevated if consistently over 90 mmhg. (27 Sep 1997) |
| differential blood pressure | The arterial blood pressure at corresponding points on the two sides of the body. (05 Mar 2000) |
| biological monitoring | This is the periodic examination of biological specimens for the purposes of monitoring their exposure to or the effects of potentially toxic chemicals to the environment. This is normally done by analysing the amounts of the toxic substances or their metabolites present in body tissues and fluids. The term is also used to mean assessment of the biological status of populations and communities of organisms at risk, in order to protect them and to gain an early warning of possible hazards to human health. (09 Oct 1997) |
| radiation monitoring | The observation, either continuously or at intervals, of the levels of radiation in a given area, generally for the purpose of assuring that they have not exceeded prescribed amounts or, in case of radiation already present in the area, assuring that the levels have returned to those meeting acceptable safety standards. (12 Dec 1998) |
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|