| ¿µ¹® | Dilatation and Curettage(D & C) | ÇÑ±Û | Àڱñܾ¼ú, ÀڱøñÈ®Àå |
|---|---|---|---|
| ¼³¸í | ÀÚ±ÃÀ̶õ žư¡ ¼öÅÂµÇ¾î¼ ºÐ¸¸Àü±îÁö ¹ßÀ°ÇÏ°í ¼ºÀåÇÏ´Â °ø°£ÀÌ´Ù. Àڱüӿ¡ º´º¯ÀÌ ÀÖ¾î ÀÓ½ÅÀÌ °è¼ÓµÉ ¼ö ¾ø°Å³ª ¾Æ´Ï¸é ´Ù¸¥ ÀÌÀ¯·Î ÀӽŵǾî Àִ žƸ¦ Á¦°ÅÇϰíÀÚ ÇÒ °æ¿ì¿¡ »ç¿ëµÇ´Â ¹æ¹ýÀÌ´Ù. ¿©±â¼ ±Ü¾î³»±â À§ÇÏ¿©´Â ¿ì¼± ÀÚ±ÃÀÇ ÀÔ±¸¿¡ ÇØ´çÇÏ´Â ÀڱøñÀ» È®Àå½ÃÄÑ¾ß ÇÑ´Ù. ¿©±â¿¡´Â ±Þ¼ÓÈ÷ È®ÀåÀ» ½ÃµµÇÏ´Â ¹ý°ú ¼¼È÷ È®ÀåÀ» ½ÃµµÇÏ´Â 2°¡Áö ¹æ¹ýÀÌ ÀÖ´Ù. ÀڱøñÀ» ±Þ¼ÓÈ÷ È®ÀåÇÒ ¶§´Â Çì°¡¸£ ¸ñ°üÈ®Àå±â(Hegar's dilatator)¸¦ »ç¿ëÇÑ´Ù. À̰ÍÀº ÀÛÀº ±Ý¼Ó¸·´ë·Î ÀÛÀº Å©±âºÎÅÍ Å« Å©±â±îÁö ´Ù¾çÇÑ Å©±â°¡ ÀÖ¾î¼ ¿ì¼± ÀÛÀº ¸·´ë·Î ½ÃÀÛÇÏ¿© Á¡Á¡ Å« Å©±âÀÇ ¸·´ë¸¦ Àڱøñ¿¡ ³Ö¾î¼ ÀڱøñÀ» È®Àå½ÃŲ´Ù. ¼¼È÷ È®Àå½Ãų ¶§´Â Laminaria tent¸¦ ¸ñ°ü¿¡ »ðÀÔÇÏ´Â ¹æ¹ýÀ» »ç¿ëÇÑ´Ù. Laminaria tent¶õ ÇØÃÊ·Î ¸¸µç ÀÛÀº ¸·´ë·Î ¼öºÐÀ» Èí¼öÇϸé Á¡Á¡ ´Ã¾î³ª´Â ¼ºÁúÀÌ ÀÖ´Ù. À̰ÍÀ» ÀÚ±ÃÀÇ ¸ñ¿¡ ³ÖÀ¸¸é À̰ÍÀÌ ¼öºÐÀ» Èí¼öÇÏ¿© ´Ã¾î³ª¹Ç·Î õõÈ÷ ÀÚ±ÃÀÇ ¸ñÀÌ ´Ã¾î³´Ù. ÀڱøñÀÌ ÃæºÐÈ÷ ´Ã¾î³ª¸é ±× ¼ÓÀ¸·Î ³¡ÀÌ ¼ù°¡¶ôó·³ »ý±ä ±â±¸¸¦ ³Ö¾î¼ ÀڱüÓÀÇ º´º¯À̳ª ÀÓ½ÅµÈ Å¾Ƹ¦ ±Ü¾î³»´Âµ¥ ¿©±â¿¡ »ç¿ëµÇ´Â ¼ù°¡¶ôó·³ »ý±ä ±â±¸¸¦ Å¥·¿À̶ó°í ÇÑ´Ù. Ãʱâ ÀÓ½ÅÁßÀý Áï À¯»ê°ú °°Àº ÀӽŰú °ü·ÃµÈ °æ¿ì»Ó¸¸ ¾Æ´Ï¶ó, ºñÀӽŠÀÚ±ÃÀÇ Àڱ󻸷Á¶Á÷ÀÇ Ã¤Ãë ¹× Á¦°Å¸¦ À§Çؼµµ ÇàÇØÁö´Â ¼ö±âÀÌ´Ù. ÀÌ´Â ¿øÄ¢ÀûÀ¸·Î ¸¶ÃëÇÏ¿¡ ½Ç½ÃµÇ´Â °ÍÀ¸·Î Àڱøñ°üÀ» È®ÀåÇÏ°í ±â±¸·Î Àڱà ³»¿ë¹°À» Á¦°ÅÇϰí Å¥·¿À¸·Î Àڱ󻺮À» ±ú²ýÀÌ ÇÑ´Ù. ÀÚ±Ãõ°øÀ̳ª ÀڱøñÀÇ ÆÄ¿ µîÀÇ À§ÇèÀÌ µû¸£¸ç, ¼ö¼úÈÄ °¨¿° ¶Ç´Â ÃâÇ÷ µî¿¡ ´ëÇÑ ÁÖÀǰ¡ ÇÊ¿äÇÏ´Ù. |
||
| ¿µ¹® | pacemaker | ÇÑ±Û | ±æÀâÀÌ, ½ÉÀ屿ÀâÀÌ |
|---|---|---|---|
| ¼³¸í | ¿ì½É¹æ°ú »ó´ëÁ¤¸ÆÀÇ ¿¬Á¢ºÎ¿¡ Àִ Ưº°ÇÑ ½Å°æÁ¶Á÷¿Í µ¿¹æ°áÀý¿¡ ÀÇÇÑ ½É¹æ¼öÃàÀÌ ¹æ½Ç°áÀý·Î Àü´ÞµÇ¸é ½É½ÇÀÇ ¼öÃàÀÌ ½ÃÀ۵ȴÙ. ½É¹æ-¹æ½Ç°áÀý-½É½Ç¿¡¼ ¹ß»ýÇÏ´Â À̼Ҽº ¶Ç´Â ÀáÀ缺 ±æÀâÀÌ´Â ºñÁ¤»óÀû ½ÉÀå±â´É¿¡¼ ³ªÅ¸³ª´Â ¼öÃàÀÇ ¿øÀÎÀÌ µÇ±âµµ ÇÑ´Ù. ½ÉÀå ±æÀâÀ̶õ ½ÉÀå±ÙÀ°À» Àü±â·Î ÀÚ±ØÇÏ¿© ½ÉÇÑ ´À¸°¸Æ¿¡¼ ½ÉÀå¹Úµ¿·üÀ» Áõ°¡½Ã۴µ¥ ¾²ÀÌ´Â Àü±âÀû ÀåÄ¡. ½ÉÀåÀÌ »ý¸í À¯Áö¿¡ ÇÊ¿äÇÑ ÃÖ¼ÒÇÑÀÇ ¼Óµµ·Îµµ ÀÚ¹ßÀûÀÎ ¼öÃàÀ» ÇÏÁö ¸øÇÒ ¶§ ½É¹ÚÁ¶À²±â°¡ ÀÏÁ¤ÇÏ°Ô °íÁ¤µÈ ¼ÓµµÀÇ Àü±âÀû ÀÚ±ØÀ» ÀϽÃÀû ¶Ç´Â ¿µ±¸ÀûÀ¸·Î º¸³¾ ¼ö ÀÖ´Ù. |
||
| ¿µ¹® | pacemaker | ÇÑ±Û | ¹Úµ¿Á¶À²±â |
|---|---|---|---|
| ¼³¸í | ¿ì½É¹æ°ú »ó´ëÁ¤¸ÆÀÇ ¿¬Á¢ºÎ¿¡ Àִ Ưº°ÇÑ ½Å°æÁ¶Á÷¿Í µ¿¹æ°áÀý¿¡ ÀÇÇÑ ½É¹æ¼öÃàÀÌ ¹æ½Ç°áÀý·Î Àü´ÞµÇ¸é ½É½ÇÀÇ ¼öÃàÀÌ ½ÃÀ۵ȴÙ. ½É¹æ-¹æ½Ç°áÀý-½É½Ç¿¡¼ ¹ß»ýÇÏ´Â À̼Ҽº ¶Ç´Â ÀáÀ缺 ±æÀâÀÌ´Â ºñÁ¤»óÀû ½É±â´É¿¡¼ ³ªÅ¸³ª´Â ¼öÃàÀÇ ¿øÀÎÀÌ µÇ±âµµ ÇÑ´Ù. ½ÉÀå ±æÀâÀ̶õ ½ÉÀå±ÙÀ°À» Àü±â·Î ÀÚ±ØÇÏ¿© ½ÉÇÑ ´À¸°¸Æ¿¡¼ ½ÉÀå¹Úµ¿·üÀ» Áõ°¡½Ã۴µ¥ ¾²ÀÌ´Â Àü±âÀû ÀåÄ¡. ½ÉÀåÀÌ »ý¸í À¯Áö¿¡ ÇÊ¿äÇÑ ÃÖ¼ÒÇÑÀÇ ¼Óµµ·Îµµ ÀÚ¹ßÀûÀÎ ¼öÃàÀ» ÇÏÁö ¸øÇÒ ¶§ ½É¹ÚÁ¶À²±â°¡ ÀÏÁ¤ÇÏ°Ô °íÁ¤µÈ ¼ÓµµÀÇ Àü±âÀû ÀÚ±ØÀ» ÀϽÃÀû ¶Ç´Â ¿µ±¸ÀûÀ¸·Î º¸³¾ ¼ö ÀÖ´Ù. |
||
| ¿µ¹® | pacemaker(of heart) | ÇÑ±Û | ½ÉÀå¹Úµ¿±â |
|---|---|---|---|
| ¼³¸í | ½ÉÀåÀÇ Àü±âÀû ÀÚ±ØÀÌ º´ÀûÀÎ »óÅ·Π¹ß»ýÇÏÁö ¾Ê°Å³ª, ȤÀº ½É½Ç·Î Àß ÀüÇØÁöÁö ¾ÊÀ» ¶§ »ç¿ëÇÑ´Ù. ÀϽÃÀû ½ÉÀå¹Úµ¿±â¿Í ¿µ±¸Àû ½ÉÀå¹Úµ¿±â°¡ ÀÖÀ¸¸ç, °¢±â ¾²ÀÌ´Â ¿ëµµ´Â º´¿¡ µû¶ó ´Ù¸£´Ù. ¿äÁò¿¡ ³ª¿À´Â ½ÉÀå ¹Úµ¿±â´Â °ÇÀüÁöÀÇ ¼ö¸íµµ ¹Ý¿µ±¸ÀûÀ̸ç, ¹Û¿¡¼ Á¶Á¤ÇÒ ¼ö ÀÖ°í, ¿îµ¿À̳ª ½ºÆ®·¹½º »óȲ¿¡ ´ëÇÑ ½ÉÀåÀÇ ºü¸¥ ¿îµ¿¿¡µµ Àß ÀûÀÀÇÒ ¼ö ÀÖµµ·Ï ¸¸µé¾îÁ® ÀÖ´Ù. |
||
| ¿µ¹® | cardiac catheterization | ÇÑ±Û | ½ÉÀåµµ°ü¼ú |
|---|---|---|---|
| ¼³¸í | ÆÈ, ´Ù¸® ¶Ç´Â ¸ñÀÇ Á¤¸ÆÀ» ÅëÇÏ¿© ½ÉÀå¿¡ ÀÛÀº Ä«Å×Å͸¦ »ðÀÔÇÏ´Â ¹ý. Ç÷¾×Ç¥º»Ã¤Ãë, ½ÉÀå³»¾ÐÃøÁ¤, ½ÉÀåÀÌ»ó°ËÃâ¿¡ »ç¿ëÇÑ´Ù. |
||
| ECG | Electro-Cardio-Graphy(-Gram); ½ÉÀüµµ = EKG 1. Conducting System Structu... |
|---|---|
| CAS | calcarine sulcus; calcific aortic stenosis; Cancer Attitude Survey; carbohydrate-active steroid; car... |
| CR | calculation rate; calculus removed; calorie-restricted; cardiac rehabilitation; cardiac resuscitatio... |
| TEAM | techniques for effective alcohol management; Training in Expanded Auxiliary Management; transfemoral... |
| CA | anterior commissure [Lat. commissura anterior]; calcium antagonist; California [rabbit]; cancer; Can... |
| PMT | Pacemaker-Mediated Tachycardia |
|---|---|
| DAS | Dyadic Adjustment Scale |
| MAC | Mental Adjustment to Cancer |
| PAIS | Psychosocial Adjustment to Illness Scale |
| SAS | Social Adjustment Scale |
| cardiac pacemaker | An electrical device which delivers a small stimulant shock to the heart to effect cardiac contraction at a pre-determined rate. Many of today's pacemakers have two main components: the electrodes and the transducer (pulse generator). The electrodes are wires which are placed into the circulatory system and make physical contact with the heart muscle. A small electrical discharge from the pacemaker electrode stimulates the muscular wall of the heart to contract, thus pumping blood in an organised fashion. The transducer is a small device, usually implanted under the skin, that generates the electrical discharge at a pre-determined frequency. Transducers can monitor your heart's rate of contraction and deliver an electrical shock only when the heart is going too slow. (27 Sep 1997) |
|---|---|
| electric cardiac pacemaker | An electric device that can substitute for the normal cardiac pacemaker, controlling the heart's rhythm by artificial electric discharges. Synonym: electronic pacemaker. (05 Mar 2000) |
| adjustment | 1. The act of adjusting, or condition of being adjusted; act of bringing into proper relations; regulation. "Success depends on the nicest and minutest adjustment of the parts concerned." (Paley) 2. Settlement of claims; an equitable arrangement of conflicting claims, as in set-off, contribution, exoneration, subrogation, and marshaling. 3. The operation of bringing all the parts of an instrument, as a microscope or telescope, into their proper relative position for use; the condition of being thus adjusted; as, to get a good adjustment; to be in or out of adjustment. Synonym: Suiting, fitting, arrangement, regulation, settlement, adaptation, disposition. Origin: Cf. F. Ajustement. See Adjust. Source: Websters Dictionary (01 Mar 1998) |
| adjustment disorders | Maladaptive reactions to identifiable psychosocial stressors occurring within a short time after onset of the stressor. They are manifested by either impairment in social or occupational functioning or by symptoms (depression, anxiety, etc.) that are in excess of a normal and expected reaction to the stressor. (12 Dec 1998) |
| social adjustment | Those types of relationships which involve the accommodation of the individual to circumstances in his social environment for the satisfaction of his needs or motives. (12 Dec 1998) |
| occlusal adjustment | Selective grinding of occlusal surfaces of the teeth in an effort to eliminate premature contacts and occlusal interferences; to establish optimal masticatory effectiveness, stable occlusal relationships, direction of main occlusal forces, and efficient multidirectional patterns, to improve functional relations and to induce physiologic stimulation of the masticatory system; to eliminate occlusal trauma; to eliminate abnormal muscle tension; to aid in the stabilization of orthodontic results; to treat peridontal and temporomandibular joint problems; and in restorative procedures. (12 Dec 1998) |
| artificial pacemaker | Any device that substitutes for the normal pacemaker and controls the rhythm of the organ; especially an electronic cardiac pacemaker, which may be implanted in the chest, with electrodes attached to the external cardiac surface, or passed through the venous circulation into the right side of the heart (pervenous pacemaker). (05 Mar 2000) |
| pacemaker | 1. <apparatus, physiology> An object or substance that influences the rate at which a certain phenomenon occurs, often used alone to indicate the natural cardiac pacemaker or an artificial cardiac pacemaker. 2. <biochemistry> A substance whose rate of reaction sets the pace for a series of interrelated reactions. (24 Mar 1998) |
| pacemaker, artificial | A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). (12 Dec 1998) |
| pacemaker failure | Failure of an artificial pacemaker to generate or deliver effective stimuli to the myocardium. (05 Mar 2000) |
| pacemaker output | Electrical energy delivered into a standard load (500 ohms resistance). (05 Mar 2000) |
| pacemaker potential | The voltage inscribed by impulses from an artificial electronic pacemaker. (05 Mar 2000) |
| pacemaker sensitivity | The minimum cardiac activity required to consistently trigger a pulse generator. (05 Mar 2000) |
| pacemaker syndrome | <syndrome> The occurrence of symptoms relating to the loss of atrial-ventricular synchrony in ventricularly paced patients, or symptoms caused by inadequate timing of atrial and ventricular contractions in paced patients. (05 Mar 2000) |
| refractory period of electronic pacemaker | The time required to restore full sensitivity after detecting cardiac activity or delivering a pacing impulse. (05 Mar 2000) |