¼±Åà - È­»ìǥŰ/¿£ÅÍŰ ´Ý±â - ESC

 
"cup electrode"¿¡ ´ëÇÑ °Ë»ö °á°úÀÔ´Ï´Ù. °Ë»ö °á°ú º¸´Â µµÁß¿¡ Tab ۸¦ ´©¸£½Ã¸é °Ë»ö âÀÌ ¼±Åõ˴ϴÙ.
´ëÇÑÀÇÇù ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 15 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
  • electrode catheter ablation
    Àü±ØÄ«Å×ÅÍÀýÁ¦(¹ý)
  • electrode paste
    Àü±ØÇ®
  • electrode potential
    Àü±ØÀüÀ§
  • ground electrode
    Á¢ÁöÀü±Ø
  • ion selective electrode
    À̿¼±ÅÃÀü±Ø
  • indifferent electrode
    ±âÁØÀü±Ø, ¹«°üÀü±Ø
  • monopolar electrode
    ´Ü±ØÀü±Ø
  • monopolar needle electrode
    ´Ü±Ø¹Ù´ÃÀü±Ø
  • multilead electrode
    ´ÙÀ¯µµÀü±Ø
  • needle electrode
    ¹Ù´ÃÀü±Ø
  • oxygen electrode method
    »ê¼ÒÀü±Ø¹ý
  • recording electrode
    ±â·ÏÀü±Ø
  • reference electrode
    ±âÁØÀü±Ø, Âü°íÀü±Ø
  • ring electrode
    °í¸®Àü±Ø
  • solid state electrode
    °íüÀü±Ø
¿¾ ´ëÇÑÀÇÇù ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 15 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
  • deflection electrode
    ÆíÇâÀü±Ø, ½ò¸²Àü±Ø
  • different electrode
    À¯°üÀü±Ø
  • electrode
    Àü±Ø
  • electrode paste
    Àü±ØÇ®
  • electrode potential
    Àü±ØÀüÀ§
  • exploring electrode
    Ž»öÀü±Ø
  • ground electrode
    Á¢ÁöÀü±Ø
  • implantation electrode
    »ðÀÔÀü±Ø
  • impolarizable electrode
    ºñºÐ±ØÀü±Ø
  • indifferent electrode
    ±âÁØÀü±Ø, ¹«°üÀü±Ø
  • ion selective electrode
    À̿¼±ÅÃÀü±Ø
  • localizing electrode
    ±¹ÇÑÀü±Ø
  • monopolar electrode
    ´Ü±ØÀü±Ø
  • monopolar needle electrode
    ´Ü±Ø¹Ù´ÃÀü±Ø
  • multilead electrode
    ´ÙÀ¯µµÀü±Ø
¿¾ ´ëÇÑÀÇÇù 3 ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 15 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
  • retinal cup
    ¸Á¸·ÇÔ¿ä(¡­ùèèê)
  • rubber cup
    ¶ó¹öÄÅ.
  • suction rubber cup
    ÈíÂø°í¹«¹è(¡­ÛÊ).
  • wet cup
    ½ÀÈí°¢(½ÀÈí°¢).
  • calomel electrode
    °¨È«<Ä®·Î¸á>Àü±Ø
  • calomel electrode
    <Ä®·Î¸á>.
  • capillary electrode
    ¸ð¼¼°üÀü±Ø(¡­ï³Ð¿)
  • concentric electrode
    ÁýÁßÀü±Ø(ó¢ñéï³Ð¿)
  • deflection electrode
    ÆíÇâÀü±Ø, ½ò¸²Àü±Ø
  • different electrode
    À¯°üÀü±Ø(êóμï³Ð¿), Ž»öÀü±Ø.
  • disk electrode
    ¿øÆÇ(ê­÷ù)Àü·ù(ï³×µ)
  • electrode
    Àü±Ø(ï³Ð¿).
  • electrode
    Àü±Ø
  • electrode catheter
    Àü±ØµµÀÚ.
  • electrode paste
    Àü±ØÇ®.
´ëÇÑ»ýÈ­ÇкÐÀÚ»ý¹°ÇÐȸ ¿ë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 6 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
  • oxygen electrode
    »ê¼ÒÀü±Ø(ß«áÈï³Ð¿)
  • pH electrode
    pH Àü±Ø(ï³Ð¿)
  • polarized electrode
    ºÐ±Ø(ÝÂп)µÈ Àü±Ø(ï³Ð¿)
  • rank electrode
    ·©Å© Àü±Ø(ï³Ð¿)
  • reference electrode
    ±âÁØ Àü±Ø(ÐññÞï³Ð¿)
  • standard electrode potential
    Ç¥ÁØ Àü±ØÀüÀ§(øöñÞï³Ð¿ï³êÈ)
KMLE ÀÇÇоà¾î »çÀü À¯»ç °Ë»ö °á°ú : 5 ÆäÀÌÁö: 2
DME degenerative myoclonus epilepsy; dimethyl diester; dimethyl ether; diphasic meningoencephalitis; dir...
Fp frontal polar electrode placement in electroencephalography
IEC injection electrode catheter; International Electrotechnical Commission; intraepithelial carcinoma; ...
ISE inhibited sexual excitement; International Society of Endocrinology; International Society of Endosc...
NEE needle electrode examination
KMLE ÀÚµ¿ÃßÃâ ÀÇÇоà¾î »çÀü À¯»ç °Ë»ö °á°ú : 3 ÆäÀÌÁö: 2
ISE Ion-Selective Electrode
SCE saturated calomal electrode
SEVC single electrode voltage clamp
CancerWEB ¿µ¿µ ÀÇÇлçÀü À¯»ç °Ë»ö °á°ú : 15 ÆäÀÌÁö: 2
carbon dioxide electrode A glass electrode in a film of bicarbonate solution covered by a thin plastic membrane permeable to carbon dioxide but impermeable to water and electrolytes; the carbon dioxide pressure of a gas or liquid sample quickly equilibrates through the membrane and is measured in terms of the resulting pH of the bicarbonate solution, as sensed by the glass electrode; commonly used to analyze arterial blood samples.
Synonym: Severinghaus electrode.
(05 Mar 2000)
redox electrode An electrode capable of measuring oxidation-reduction potential.
See: quinhydrone electrode.
Synonym: redox electrode.
(05 Mar 2000)
reference electrode An electrode expected to have a constant potential, such as a calomel electrode, and used with another electrode to complete an electrical circuit through a solution; e.g., when a reference electrode is used with a glass electrode for pH measurement, changes in voltage between the two electrode's can be attributed to the effects of pH on the glass electrode alone.
(05 Mar 2000)
glass electrode A thin-walled glass bulb containing a standard buffer solution, quinhydrone, and a platinum wire; when immersed in an unknown solution, a potential difference develops that varies with the pH of the unknown solution; this difference can be made to give the pH; used in pH meters.
(05 Mar 2000)
central terminal electrode In electrocardiography, an electrode in which connections from the three limbs (right arm, left arm, and left leg) are joined and led to the electrocardiograph to form the indifferent electrode, theoretically at zero potential for the system.
(05 Mar 2000)
Clark electrode An oxygen electrode consisting of the tip of a platinum wire exposed to a thin film of electrolyte covered by a plastic membrane permeable to oxygen but not to water or the electrolyte. When a certain voltage is applied, oxygen is destroyed at the platinum surface; the flow of current is then proportional to the rate at which oxygen can diffuse to the platinum surface from the gas or liquid sample outside the membrane, and is thus a measure of the oxygen pressure in the sample; commonly used to measure oxygen pressure in arterial blood samples.
(05 Mar 2000)
positive electrode <microscopy> The electrode to which a major flow of electrons takes place internally (as in a cathode-ray tube) or to which an external positive voltage supply is connected.
(05 Aug 1998)
Severinghaus electrode A glass electrode in a film of bicarbonate solution covered by a thin plastic membrane permeable to carbon dioxide but impermeable to water and electrolytes; the carbon dioxide pressure of a gas or liquid sample quickly equilibrates through the membrane and is measured in terms of the resulting pH of the bicarbonate solution, as sensed by the glass electrode; commonly used to analyze arterial blood samples.
Synonym: Severinghaus electrode.
(05 Mar 2000)
hydrogen electrode The ultimate standard of reference in all pH determinations, limited and technically difficult to use, consisting of a piece of spongy platinum black partly immersed in a solution in a small glass tube; the tube above the solution is filled with hydrogen gas that is bubbled through the solution and absorbed by the platinum; the electrode thus measures the potential between H2 and H+, the "standard" potential of which (1 atmosphere, 1 molar) is taken as zero; hence, the hydrogen electrode potential measures [H+] or pH.
(05 Mar 2000)
silent electrode In unipolar electrocardiography, a remote electrode placed either upon a single limb or connected with the central terminal and paired with an exploring electrode; the indifferent electrode is supposed to contribute little or nothing to the resulting record.
Synonym: dispersing electrode, silent electrode.
(05 Mar 2000)
negative electrode <chemistry, physics> The electrode in an electrochemical cell toward which cations are drawn and where reduction occurs.
The negatively charged electrode in a vacuum tube.
(16 Mar 1998)
dispersing electrode In unipolar electrocardiography, a remote electrode placed either upon a single limb or connected with the central terminal and paired with an exploring electrode; the indifferent electrode is supposed to contribute little or nothing to the resulting record.
Synonym: dispersing electrode, silent electrode.
(05 Mar 2000)
indifferent electrode In unipolar electrocardiography, a remote electrode placed either upon a single limb or connected with the central terminal and paired with an exploring electrode; the indifferent electrode is supposed to contribute little or nothing to the resulting record.
Synonym: dispersing electrode, silent electrode.
(05 Mar 2000)
quinhydrone electrode One of several oxidation-reduction electrode's in which the ratio of the two forms (quinone-quinhydrone), determined by the hydrogen ion concentration, sets up a potential that can be measured and converted to a pH value (fails above pH 8).
(05 Mar 2000)
ion selective electrode An electrode half cell, with a semi permeable membrane that is permeable only to a single ion. The electrical potential measured between this and a reference half cell (e.g. A calomel electrode) is thus the Nernst potential for the ion. Given that the solution filling the ion selective electrode is known, the activity (rather than concentration) of the ion in the unknown solution can be measured. Commercial ion selective electrodes frequently use a hydrophobic membrane containing an ionophore, such as valinomycin (for potassium) or monensin (for sodium). A pH electrode is made with a thin membrane of pH sensitive (i.e. Proton permeable) glass.
(18 Nov 1997)
ÇÑ¿µ/¿µÇÑ »çÀü À¯»ç °Ë»ö °á°ú : 13 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
  • drinking cup
    ¼úÀÜ
  • flower cup
    ²É¹Þħ
  • force cup
    X;=PLUMBER'S HELPER
  • fruit cup
    Àß°Ô ½ã °úÀÏÀ» ÄÅ¿¡ ³ÖÀº µðÀúÆ®
  • grace cup
    °Ç¹è(ÀÇ ÀÜ);Ãà¹è;(Ãâ¹ßÀü)À̺°ÀÇ ¼úÀÜ
  • grease cup
    ±×¸®½ºÄÅ(±â°è¿¡ ºÙ¾î ÀÖ´Â)
  • loving cup
    ¿ì¾ÖÀÇ ¼úÀÜ
  • measuring cup
    (´«±Ý ÀÖ´Â)°è·®ÄÅ
  • painted cup
    Çö»ï°úÀÇ ½Ä¹°(¹Ì±¹»ê)
  • porous cell(cup)
    Ãʹú±¸ÀÌ Àڱ⠿ë±â
  • race-cup
    raceÀÇ ¿ì½Â¹è
  • racing cup
    »ó¹è;¿ì½Â¹è(°æ¸¶µîÀÇ)
  • stirrup cup
    (¸¶»ó¿¡¼­ÀÇ)ÀÛº°ÀÇ ¼úÀÜ
ÀÌ ¾Æ·¡ ºÎÅÍ´Â °á°ú°¡ ¾ø½À´Ï´Ù.
KMLE ¾àǰ/ÀǾàǰ ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • Á¦Ç°¸í
    ¼ººÐ/ÇÔ·®
    ±¸ºÐ/º¸Çè±Þ¿©
KMLE ¾àǰ/ÀǾàǰ À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • Á¦Ç°¸í
    ¼ººÐ/ÇÔ·®
    ±¸ºÐ/º¸Çè±Þ¿©
¾Ë±â½¬¿î ÀÇÇпë¾îÇ®ÀÌÁý, ¼­¿ïÀÇ´ë ±³¼ö ÁöÁ¦±Ù, °í·ÁÀÇÇÐ ÃâÆÇ ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
¾Ë±â½¬¿î ÀÇÇпë¾îÇ®ÀÌÁý, ¼­¿ïÀÇ´ë ±³¼ö ÁöÁ¦±Ù, °í·ÁÀÇÇÐ ÃâÆÇ À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
´ëÇÑÀÇÇù ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
´ëÇÑÀÇÇù Çʼö ÀÇÇпë¾îÁý »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
´ëÇÑÀÇÇù Çʼö ÀÇÇпë¾îÁý »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
¿¾ ´ëÇÑÀÇÇù ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
¿¾ ´ëÇÑÀÇÇù 2 ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
¿¾ ´ëÇÑÀÇÇù 2 ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
¿¾ ´ëÇÑÀÇÇù 3 ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
´ëÇÑÇØºÎÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
´ëÇÑÇØºÎÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
´ëÇѽŰæ¿Ü°úÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
    ÇÑÀÚ
´ëÇѽŰæ¿Ü°úÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
    ÇÑÀÚ
´ëÇѱâ»ýÃæÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
´ëÇѱâ»ýÃæÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
´ëÇÑ»ýÈ­ÇкÐÀÚ»ý¹°ÇÐȸ ¿ë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
KI ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
KI ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
KMLE ÀÇÇоà¾î »çÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
KMLE ÀÚµ¿ÃßÃâ ÀÇÇоà¾î »çÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
ÀÇÇÐ³í¹® ¾àÀÚ(Pubmed/Entrez) °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
Çѱ¹Ç¥ÁØÁúº´»çÀκзù ¾àÀÚ ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ÄÚµå
    ¿µ¹®
    ÇѱÛ
Çѱ¹Ç¥ÁØÁúº´»çÀκзù ¾àÀÚ À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ÄÚµå
    ¿µ¹®
    ÇѱÛ
°æºÏ´ë Ä¡°ú´ëÇÐ ±¸°­³»°ú ±³½Ç »çÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
    ¼³¸í
°æºÏ´ë Ä¡°ú´ëÇÐ ±¸°­³»°ú ±³½Ç »çÀü À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
    ¼³¸í
CancerWEB ¿µ¿µ ÀÇÇлçÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
MeSH(Medical Subject Headings) ¸ÂÃã °Ë»ö (http://www.nlm.nih.gov) °á°ú : 0 ÆäÀÌÁö: 2
MeSH(Medical Subject Headings) À¯»ç °Ë»ö (http://www.nlm.nih.gov) °á°ú : 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - Merriam-Webster's ÀÇÇлçÀü ¸ÂÃã °Ë»ö (https://www.merriam-webster.com) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - Merriam-Webster's ÀÇÇлçÀü À¯»ç °Ë»ö (https://www.merriam-webster.com) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - A.D.A.M. Medical Encyclopedia ¸ÂÃã °Ë»ö (http://www.nlm.nih.gov) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - A.D.A.M. Medical Encyclopedia À¯»ç °Ë»ö (http://www.nlm.nih.gov) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - MedlinePlus Health Topics ¸ÂÃã °Ë»ö (http://www.nlm.nih.gov) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - MedlinePlus Health Topics À¯»ç °Ë»ö (http://www.nlm.nih.gov) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - µå·¯±×ÀÎÆ÷ ¾àÇÐ Á¤º¸ ¸ÂÃã °Ë»ö (http://www.druginfo.co.kr) °á°ú: 0 ÆäÀÌÁö: 2
Á¦Ç°¸í
ÆÇ¸Å»ç
º¸ÇèÄÚµå ¼ººÐ/ÇÔ·®
±¸ºÐ/º¸Çè±Þ¿©
¿ÜºÎ ¸µÅ© - µå·¯±×ÀÎÆ÷ ¾àÇÐ Á¤º¸ À¯»ç °Ë»ö (http://www.druginfo.co.kr) °á°ú: 0 ÆäÀÌÁö: 2
Á¦Ç°¸í
ÆÇ¸Å»ç
º¸ÇèÄÚµå ¼ººÐ/ÇÔ·®
±¸ºÐ/º¸Çè±Þ¿©
¿ÜºÎ ¸µÅ© - WebMD.com Drug Reference ¸ÂÃã °Ë»ö (http://www.webmd.com) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - WebMD.com Drug Reference À¯»ç °Ë»ö (http://www.webmd.com) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - Drug.com Drugs by Medical Condition ¸ÂÃã °Ë»ö (http://www.drugs.com) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - Drug.com Drugs by Medical Condition À¯»ç °Ë»ö (http://www.drugs.com) °á°ú: 0 ÆäÀÌÁö: 2
KMLE À¥ ¿ë¾î ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
KMLE À¥ ¿ë¾î À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
ÇÑ¿µ/¿µÇÑ »çÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
  • ¿µ¹®
    ÇѱÛ
WordNet ÀÏ¹Ý ¿µ¿µ »çÀü °Ë»ö °á°ú : 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - American Heritage Dictionary ¿µ¿µ»çÀü ¸ÂÃã °Ë»ö (https://www.ahdictionary.com) °á°ú: 0 ÆäÀÌÁö: 2
¿ÜºÎ ¸µÅ© - American Heritage Dictionary ¿µ¿µ»çÀü À¯»ç °Ë»ö (https://www.ahdictionary.com) °á°ú: 0 ÆäÀÌÁö: 2
ÅëÇÕ°Ë»ö ¿Ï·á