| ¿µ¹® | blood collection | ÇÑ±Û | äÇ÷ |
|---|---|---|---|
| ¼³¸í | 1. ¸ð¼¼°üÇ÷ : Ç÷±¸¼ö-Ç÷¼ÒÆÇ¼ö °è»ê, Ç÷»ö¼Ò·®, Ç÷±¸¿ëÀûÃøÁ¤, µµ¸»Ç¥º»Á¦ÀÛ µîÀ» ÇÒ¶§ »ç¿ëµÈ´Ù. ±ÓºÒ ¶Ç´Â ¼Õ°¡¶ô³¡¹Ù´Ú¸éÀ» ÃæºÐÈ÷ ¸¶ÂûÇÑ ´ÙÀ½, ¾ËÄڿ÷Π¼Òµ¶-°ÇÁ¶½ÃÄѼ, ÀÛÀº Ä® ¶Ç´Â Á¾µÎħ ȤÀº 1mmÀÇ ÁÖ»çħÀ¸·Î 2~3mmÀÇ ±íÀ̱îÁö Â´Ù. ¸ÇóÀ½ Çǹæ¿ïÀº ´Û¾Æ³½ ÈÄ ´ÙÀ½ Ç͹æ¿ïÀ» °Ë»ç¿¡ ÀÌ¿ëÇÑ´Ù. 2. Á¤¸ÆÇ÷ : ´ë·®ÀÇ Ç÷¾×À» ¿äÇÏ´Â °æ¿ì¿¡ »ç¿ëÇÑ´Ù. º¸Åë (ÆÈ²ÞÄ¡Á¤ÁßÇǺÎ)ÁÖÁ¤ÁßÇÇÁ¤¸ÆÀ» Â¸ç, ¿µÀ¯¾ÆÀÇ °æ¿ì¿¡´Â ¿Ü°æÁ¤¸ÆÀ» ¼±ÅÃÇϱ⵵ ÇÑ´Ù. ÁöÇ÷¿ë °í¹«ÁÙ·Î »ó´ÜÀ» ÃÖÀúÇ÷¾Ð¿¡ »ó´çÇÏ´Â Á¤µµ·Î ¹°í, ÁÖ¸ÔÀ» ²À Áã°Ô ÇÏ¿© Á¤¸ÆÀ» ³ëÃâ½ÃŲ ÈÄ ¸ê±Õ°ÇÁ¶ÁÖ»ç±â¸¦ Ç÷°ü³»¿¡ »ðÀÔÇÑ´Ù. °ð ¹Ù·Î °í¹«ÁÙ°ú ÁÖ¸ÔÀ» Ç®°í äÇ÷À» ÇÑ ´ÙÀ½ Ç÷¾×À» ½ÃÇè°ü¿¡ ³Ö´Â´Ù. 2ºÐÀÌ»óÀÇ Á¤¸Æ ¿ïÇ÷Àº Ç÷¾×¼º»ó¿¡ º¯È¸¦ °¡Á®¿Â´Ù. 2. µ¿¸ÆÇ÷ : À§ÆÈµ¿¸Æ ¶Ç´Â ³Ò´Ù¸® µ¿¸ÆÀ» »ç¿ëÇÏ¿© õÀںθ¦ ¼Òµ¶ÇÑ ´ÙÀ½, ÇÁ·ÎÄ«ÀÎ ±¹¼Ò¸¶Ã븦 ÇÑ´Ù. äÇ÷ÀÚ ¿Þ¼ÕÀÇ °¡¿îµ¥¼Õ°¡¶ô°ú µÑ°¼Õ°¡¶ôÀ¸·Î µ¿¸ÆÀ» °íÁ¤Çϰí, ÁÖ»çħÀ» µ¿¸Æ¿¡ 45~65¡ÉÀÇ °¢µµ·Î Âñ·¯ ³Ö¾î äÇ÷ ÈÄ ¸öÂʵ¿¸ÆÀ» ¾öÁö¼Õ°¡¶ôÀ¸·Î ¾Ð¹ÚÇÏ¸é¼ ÁÖ»çħÀ» »©°í, ±× µÚ 5ºÐ°£Âë Â ºÎÀ§¸¦ ¾Ð¹ÚÇÑ´Ù. |
||
| ¿µ¹® | blood-brain barrier(BBB) | ÇÑ±Û | Ç÷³úÀ庮 |
|---|---|---|---|
| ¼³¸í | ³ú¿Í ô¼ö¿¡´Â Ç÷·ù·ÎºÎÅÍ ¾î¶² ¹°ÁúÀÌ À¯ÀԵǴ °ÍÀ» ¸·´Â À庮ÀÌ´Ù. À̰ÍÀº ³ú¿Í ô¼ö¿¡ Á¸ÀçÇÏ´Â ¸ð¼¼Ç÷°üÀÇ Åõ°ú¼ºÀÌ ºñ±³Àû ´Ù¸¥ ¸ð¼¼Ç÷°üÀÇ Åõ°ú¼ºº¸´Ù ¶³¾îÁö±â ¶§¹®ÀÌ´Ù. |
||
| ¿µ¹® | blood sugar | ÇÑ±Û | Ç÷´ç |
|---|---|---|---|
| ¼³¸í | Ç÷¾× ¼Ó¿¡ Æ÷ÇԵǾî ÀÖ´Â Æ÷µµ´ç. ³ú¿Í ÀûÇ÷±¸ÀÇ ¿¡³ÊÁö¿øÀÌ µÇ°í, ±× ¾çÀº ¿îµ¿, ½Ä»ç µûÀ§¿¡ ÀÇÇÏ¿© ´Þ¶óÁø´Ù. °Ç°ÀÎÀÇ ¾ÆÄ§ °øº¹½Ã Ç÷Áß Æ÷µµ´ç ³óµµ´Â 60~100mg/dL ÀÌÁö¸¸ ±âŸÀÇ ´çÁú Áï °ú´ç, °¥¶ôÅ佺, 5ź´çÀº ¹Ì·®À̸ç ÀϹÝÀûÀ¸·Î Ç÷´çÀ̶ó Çϸé Ç÷Á߯÷µµ´çÀ» ÀǹÌÇÑ´Ù. Ç÷´çÀº »ýüÀÇ ¿¡³ÊÁö¿øÀ¸·Î¼ °¡Àå Áß¿äÇÑ ¹°ÁúÀÌ´Ù. ±× ³óµµ´Â Àå°üÀ¸·ÎºÎÅÍÀÇ Èí¼ö, °£¿¡ ÀÖ¾î¼ÀÇ ´ç½Å»ý°ú ±Û¸®ÄÚ°ÕÀÌ ÇÕ¼º-ºÐÇØ, ¸»ÃÊÁ¶Á÷ÀÇ ´çÀÌ¿ë ÄáÆÏÀ¸·ÎºÎÅÍÀÇ ¹è¼³ µî ¿©·¯ ÀÎÀÚ¿¡ ÀÇÇØ Á¿ìµÇ¸ç ±× Á¶Àý¿¡´Â ÀÚÀ²½Å°æ°ú °¢Á¾ È£¸£¸óÀÌ ¹ÐÁ¢ÇÏ°Ô °ü°èÇÑ´Ù. ƯÈ÷ Ç÷´çÀúÇÏÀÛ¿ë¿¡´Â Àν¶¸°ÀÌ, ±×¸®°í Ç÷´ç»ó½ÂÀÛ¿ë¿¡´Â ¿¡Çdz×ÇÁ¸°, ±Û·çÄ«°ï, ¼ºÀåÈ£¸£¸ó, ºÎ½Å°ÑÁúÈ£¸£¸ó, ºÎ½Å°ÑÁúÀÚ±ØÈ£¸£¸ó, °©»ó»ù È£¸£¸óÀÌ °ü°è°¡ ÀÖÀ¸¸ç ±×°ÍµéÀÇ ´ëÇ× ¹× ÇùÁ¶ÀÛ¿ë¿¡ ÀÇÇØ Ç÷´çÄ¡°¡ Á¶ÀýµÈ´Ù. |
||
| ¿µ¹® | blood pressure | ÇÑ±Û | Ç÷¾Ð |
|---|---|---|---|
| ¼³¸í | Ç÷¾ÐÀ̶õ Ç÷°ü¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»ÇÏ´Â °ÍÀ¸·Î ´ë°³ Ưº°ÇÑ ¼³¸íÀÌ ¾øÀ¸¸é µ¿¸ÆÀÇ ¾Ð·ÂÀ» ¸»ÇÑ´Ù. Ç÷¾Ð¿¡´Â ¼öÃà±âÇ÷¾Ð(systolic blood pressure)°ú À̿ϱâÇ÷¾Ð(diastolic blood pressure)ÀÌ ÀÖ´Ù. ¼öÃà±âÇ÷¾ÐÀ̶õ ½ÉÀåÀÌ ¼öÃàÇÒ °æ¿ì¿¡ µ¿¸Æ¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»Çϰí, À̿ϱâ Ç÷¾ÐÀ̶õ ½ÉÀåÀÌ ÀÌ¿ÏÇÒ °æ¿ì¿¡ µ¿¸Æ¿¡ °É¸®´Â ¾Ð·ÂÀ» ¸»ÇÑ´Ù. ´ç¿¬È÷ ¼öÃà±â Ç÷¾ÐÀÌ À̿ϱâ Ç÷¾Ðº¸´Ù ³ô´Ù. Ç÷¾ÐÀ» ¸»ÇÒ ¶§¿¡ ¿¹¸¦ µé¾î 120/80mmHgÀ̶ó°í Àû´Â °ÍÀÇ ¾ÕÀÇ °ÍÀº ¼öÃà±â Ç÷¾ÐÀ» ÀǹÌÇÏ°í µÚ¿¡ Àû´Â 80Àº À̿ϱâ Ç÷¾ÐÀ» ÀǹÌÇÑ´Ù. |
||
| ISIS | image selected in vivo spectroscopy; imaging science and information system; information system-imag... |
|---|---|
| MDIS | medical diagnostic imaging support; medical diagnostic imaging system |
| CBF | capillary blood flow; cerebral blood flow; ciliary beat frequency; coronary blood flow; cortical blo... |
| HBF | hand blood flow; hemispheric blood flow; hemoglobinuric bilious fever; hepatic blood flow; hypothala... |
| GBP scan | Gated Blood Pool (cardiac) scan = GBPS 1. LV ±â´É ÃøÁ¤ 2. ... |
| adrenal imaging | <radiology> Cortex, I-131 iodo-cholesterol, not widely used due to high rad dose and 4-15 day delayed imaging, medulla, search for pheo, MIBG (I-131 meta-iodobenzylguanidine) (12 Dec 1998) |
|---|---|
| adrenal medullary imaging | <investigation, radiology> A nuclear scan that images the adrenal glands after a radioactive tracer is injected into the bloodstream. This test is useful in detecting a pheochromocytoma, particularly if it not within the adrenal gland. (27 Sep 1997) |
| backscattered electron imaging | <microscopy> The production of backscattered electrons from a sample varies directly with the specimen's average atomic number, higher atomic number elements produce more backscattered electrons than lower atomic number ones. Detection of Backscattered Electrons is achieved by using a donut shaped solid state saemiconductor device mounted on the bottom of the objective lens. When Backscattered Electrons strike the detector electron-hole pairs are created which are then counted. This quantity is translated into a pixel intensity and displayed on the CRT, forming the image. By splitting the detector into halves (or quadrants) differences in the signal level on the individual detector segments provide surface topography information. (05 Aug 1998) |
| bone: gallium imaging | <radiology> Increased activity in: active osteomyelitis (90% sensitivity: better than Tc-99m MDP), sarcoma, cellulitis, septic arthritis, rheumatoid arthritis, Paget disease, metastases (65% sensitivity: than for bone agents) see: gallium: indications (12 Dec 1998) |
| bright field imaging | <microscopy> An imaging mode in a transmission electron microscopy that uses only unscattered Electrons to form the image. Contrast in such an image is due entirely to mass-thickness variations in amorphous samples, and may include diffraction contrast in crystalline samples. (05 Aug 1998) |
| radionuclide imaging | Process whereby a radionuclide is injected or measured (through tissue) from an external source, and a display is obtained from any one of several rectilinear scanner or gamma camera systems. The image obtained from a moving detector is called a scan, while the image obtained from a stationary camera device is called a scintiphotograph. (12 Dec 1998) |
| Magnetic Resonance Imaging | A special imaging technique used to image internal stuctures of the body, particularly the soft tissues. An MRI image is often superior to a normal X-ray image. It uses the influence of a large magnet to polarize hydrogen atoms in the tissues and then monitors the summation of the spinning energies within living cells. Images are very clear and are particularly good for soft tissue, brain and spinal cord, joints and abdomen. These scans may be used for detecting some cancers or for following their progress. Acronym: MRI (11 Nov 1997) |
| magnetic resonance imaging, cine | A type of imaging technique used primarily in the field of cardiology. By coordinating the fast gradient-echo mri sequence with retrospective ecg-gating, numerous short time frames evenly spaced in the cardiac cycle are produced. These images are laced together in a cinematic display so that wall motion of the ventricles, valve motion, and blood flow patterns in the heart and great vessels can be visualised. (12 Dec 1998) |
| malignant melanoma: gallium imaging | <radiology> Greater than50% sensitivity for primary and metastatic sites: 73% sensitivity if lesion is greater than 2 cm, 17% sensitivity if less than 2 cm, see: gallium: indications malignant melanoma (12 Dec 1998) |
| ratio imaging fluorescence microscopy | <procedure> A method of measurement of intracellular pH or intracellular calcium levels, using a fluorescent probe molecule (see fura-2), in which the two different excitation wavelengths are used and the emitted light levels compared. If emission at one wavelength is sensitive to the intracellular ion level and emission at the other wavelength is not, then standardisation for intracellular probe concentration, efficiency of light collection, inactivation of probe and thickness of cytoplasm can all be performed automatically. (17 Dec 1997) |
| ventilation/perfusion lung imaging | <radiology> See: ventilation agents, perfusion agents, Biello-Siegel criteria (12 Dec 1998) |
| phantoms, imaging | Devices or objects in various imaging techniques used to visualise or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with X-ray or ultrasonic machines. (12 Dec 1998) |
| myocardial infarct imaging | <radiology> Tc-99m pyrophosphate (PYP) 20 mCi, peak abnormality 2-3 days, often falsely negative before 2 days, abnormal for 7-10 days, mechanism: calcium influx into ischemic cells, PYP incorporated into crystalline structure, analogous to hydroxyapatite see: nuclear cardiology (12 Dec 1998) |
| myocardial perfusion imaging | <radiology> (thallium scanning) thallium (Tl) 201, acts as potassium analog, dose 2.0 - 3.0 mCi at peak exercise, 4% of injected dose reaches myocardium, imaging: exercise (1-5 min), redistribution (3-4 hrs), views: anterior, LAO 45', left lateral, interpretation: normal, reversible abnormalitymost likely to be exercise-induced ischemia, nonreversible abnormalitymost likely to be prior myocardial infarction, reverse redistribution most likely to be normal areas wash out faster, lung activity most likely to be LV failure during exercise see also: dipyridamole test, nuclear cardiology (12 Dec 1998) |
| hepatobiliary imaging | <radiology> The hepatobiliary scan (Tc-99m DISIDA or MBF) is the initial procedure of choice to diagnose acute cholecystitis., Sensitivity 95% False negatives: acalculous cholecystitis, Specificity 95% False positives: non-fasting state, alcoholism, parenteral nutrition (TPN), acute pancreatitis, recent narcotic use, hepatocellular disease (12 Dec 1998) |
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|