| ¿µ¹® | quality control | ÇÑ±Û | Á¤µµ°ü¸®, ǰÁú°ü¸®, Áú°ü¸® |
|---|---|---|---|
| ¼³¸í | °úÇÐÀû ¿ø¸®¸¦ ÀÀ¿ëÇÏ¿© Á¦Ç°Ç°ÁúÀÇ À¯Áö-Çâ»óÀ» ±âÇϱâ À§ÇÑ °ü¸®. ³ÐÀº ¶æÀ¸·Î´Â °¡Àå ½ÃÀ强ÀÌ ³ôÀº Á¦Ç°À» °¡Àå °æÁ¦ÀûÀ¸·Î »ý»êÇϱâ À§ÇÑ ÀÏ·ÃÀÇ Ã¼°ÔÀû Á¶Ä¡¸¦ °¡¸®Å°³ª, ÀϹÝÀûÀ¸·Î´Â ¾ÕÀÇ Á¼Àº ¶æÀÇ ÇØ¼®ÀÌ Åë¿ëµÈ´Ù. ÃʱâÀÇ QC´Â ÀüÁ¦Ç°¿¡ ´ëÇØ Ä¡¼ö-Áß·®-üÀûÀ̳ª Àç·áÀÇ ÈÇÐÀû ¼ººÐ µîÀ» ÃøÁ¤Çϰí, ±×°ÍÀ» ¹Ì¸® Á¤ÇØ ³õÀº ǰÁúÇ¥Áذú ºñ±³ÇÏ¿© ÀûºÎ¸¦ ÆÇÁ¤ÇÏ´Â ¹æ¹ýÀÌ ÃëÇØÁ³´Ù. |
||
| ¿µ¹® | coagulation time | ÇÑ±Û | ÀÀ°í½Ã°£ |
|---|---|---|---|
| ¼³¸í | Ç÷¾×ÀÀ°í¶õ ÁöÇ÷ÀÇ ÇÑ °úÁ¤À¸·Î ¼¶À¯¼Ò¶õ ¹°ÁúÀ» ¸¸µé¾î ³»´Â °úÁ¤ÀÌ´Ù. ÀÌ ¼¶À¯¼Ò¶õ ¹°ÁúÀº ¼Õ»óµÈ Ç÷°üÀÇ ºÎÀ§¿¡ ÀÛ¿ëÇÏ¿© ¿©·¯ °¡Áö ¼¼Æ÷µéÀ» ¾ô¾î ¹´Â ¿ªÇÒÀ» ÇÏ¿© °á±¹ ¼Õ»óµÈ Ç÷°ü¿¡¼ Ç÷¾×ÀÇ ¼Ò½ÇÀ» ¸·´Â´Ù. Ç÷¾×ÀÀ°í´Â ´ÙÀ½°ú °°Àº 3´Ü°è·Î ÀÌ·ç¾îÁø´Ù. ù¹øÂ° ´Ü°è´Â Ç÷°ü¼Õ»ó¿¡ ÀÇÇØ¼ prothrombin activator¶ó´Â °ÍÀÌ ¸¸µé¾îÁö´Â ´Ü°èÀÌ´Ù. µÎ¹øÂ° ´Ü°è´Â ÀÌ prothrombin activator¶ó´Â ¹°Áú¿¡ ÀÇÇØ¼ Ç÷¾×¼Ó¿¡ ÀÖ´Â ÇÁ·ÎÆ®·ÒºóÀ̶ó´Â ¹°ÁúÀÌ Æ®·ÒºóÀ̶ó´Â ¹°Áú·Î ¹Ù²î´Â ´Ü°èÀÌ´Ù. ¼¼¹øÂ° ´Ü°è´Â Æ®·ÒºóÀ̶ó´Â ¹°Áú¿¡ ÀÇÇØ¼ ¼¶À¯¼Ò¿øÀ̶ó´Â ¹°ÁúÀÌ ¼¶À¯¼ÒÀ¸·Î ¹Ù²î´Â ´Ü°èÀÌ´Ù. ÀÀ°íÀÛ¿ëÀº Å©°Ô 2°¡Áö·Î ³ª´µ´Âµ¥, ¿ÜÀμº ÀÀ°íÀÎÀÚ¿Í ³»Àμº ÀÀ°íÀÎÀÚ°¡ ±×°ÍÀÌ´Ù. ¿ÜÀμº ÀÀ°íÀÎÀÚ¿Í ³»Àμº ÀÀ°íÀÎÀÚ´Â °¢±â º°°³·Î ÀÛ¿ëÇÏÁö¸¸, °á±¹Àº ¸¶Áö¸· °úÁ¤¿¡¼ Çϳª·Î ¸¸³ª¼ ¼¶À¯¼Ò¿øÀ» ¼¶À¯¼Ò(ÀÀ°íÀÛ¿ëÀÇ ¸¶Áö¸· ´Ü°è¿¡ »ý¼ºµÇ¸ç ´Ü´ÜÇϰí Ç®¸®Áö ¾Ê´Â ¸ÅµìÀ» Çü¼ºÇÏ¿© ÁöÇ÷ÀÛ¿ëÀ» ¿Ï¼ºÇÑ´Ù)À¸·Î ¸¸µé¾î ÀÀ°íÀÛ¿ëÀ» ³ªÅ¸³½´Ù. |
||
| ¿µ¹® | bleeding time | ÇÑ±Û | ÃâÇ÷½Ã°£ |
|---|---|---|---|
| ¼³¸í | ¸ö¿¡ »óó°¡ ³ª¼ ÃâÇ÷ÀÌ ÀÖ¾úÀ» °æ¿ì¿¡ Çǰ¡ ¸Ü´Âµ¥ ±îÁö °É¸®´Â ½Ã°£À» ÃâÇ÷½Ã°£À̶ó°í ÇÑ´Ù. »ç¶÷ÀÇ ¸ö¿¡ »óó°¡ ³ª¼ ÃâÇ÷ÀÌ ÀÖÀ» °æ¿ì¿¡ À̰ÍÀ» ¸·°í ÇǸ¦ ´õÀÌ»ó ³ªÁö ¾Ê°Ô ÇÏ´Â °ÍÀ» ÁöÇ÷À̶ó°í ÇÑ´Ù. ÁöÇ÷ÀÇ °úÁ¤¿¡´Â Å©°Ô µÎ °¡Áö ´Ü°è°¡ ÀÖ´Ù. ù¹øÂ° ´Ü°è´Â Ç÷¼ÒÆÇµéÀÌ »óó°¡ ³ª¼ ¼Õ»óµÈ Ç÷°üÀÇ ºÎÀ§¸¦ ¸·´Â °ÍÀÌ´Ù. ÀÌ·¸°Ô ÇÏ¸é ¿ì¼± Ç÷°üÀÇ ¼Õ»óºÎÀ§·ÎºÎÅÍ Çǰ¡ ³ª¿À´Â °ÍÀ» ¸·À» ¼ö°¡ ÀÖ´Ù. ´ÙÀ½ÀÇ ´Ü°è´Â »óó¸¦ ¸·°í ÀÖ´Â Ç÷¼ÒÆÇÀ§¿¡ ¿©·¯ °¡Áö ¹°ÁúµéÀÌ ÀÛ¿ëÇØ¼ ´õ¿í ´Ü´ÜÇÏ°Ô ÇÏ¿© »óó°¡ ³ Ç÷°ü¿¡¼ Çǰ¡ »õ´Â °ÍÀ» ¿µ±¸È÷ ¸·´Â °ÍÀÌ´Ù. ½±°Ô ¸»Çϸé Ç÷¼ÒÆÇÀº º®µ¹¿¡ ÇØ´çÇÏ´Â °ÍÀÌ°í µÎ¹øÂ° °úÁ¤¿¡ Âü¿©ÇÏ´Â ¹°ÁúµéÀº ½Ã¸àÆ®¿¡ ÇØ´çÇÏ´Â °ÍÀÌ´Ù. ÀÌ µÎ °úÁ¤ÀÌ ¿ÏÀüÇÒ °æ¿ì¿¡ ÁöÇ÷ÀÌ ¼øÁ¶·Ó°Ô ÀϾÙ. ÃâÇ÷½Ã°£Àº À§¿¡¼ ¼³¸íÇÑ ÁöÇ÷ÀÇ µÎ°¡Áö °úÁ¤ Áß¿¡¼ ù¹øÂ° °úÁ¤¿¡ ÀÇÇØ¼¸¸ ¿µÇâÀ» ¹Þ´Â´Ù. Áï ¼Õ»óµÈ Ç÷°üÀ» ¸·¾ÆÁÖ´Â º®µ¹¿¡ ÇØ´çÇÏ´Â Ç÷¼ÒÆÇÀÇ ±â´É¸¸ Á¤»óÀÏ °æ¿ì¿¡ ÃâÇ÷½Ã°£Àº Á¤»óÀ¸·Î ³ª¿Â´Ù. ¸¸¾à Ç÷¼ÒÆÇÀÇ ±â´É¿¡ ÀÌ»óÀÌ ÀÖ´Â °æ¿ì¿¡´Â ÀÚ¿¬È÷ ÃâÇ÷½Ã°£ÀÌ ±æ¾îÁø´Ù. |
||
| ¿µ¹® | prothrombin time | ÇÑ±Û | ÇÁ·ÎÆ®·Òºó½Ã°£ |
|---|---|---|---|
| ¼³¸í | ÇÁ·ÎÆ®·ÒºóÀº °£¿¡¼ ÇÕ¼ºµÇ´Â ºñŸ¹Î K ÀÇÁ¸¼º ÀÀ°í´Ü¹éÁúÀÇ ÇϳªÀ̸ç, ÇÁ·ÎÆ®·Òºó½Ã°£Àº ¿ÜÀΰè ÀÀ°íȰ¼ºÀ» Á¾ÇÕÀûÀ¸·Î ƯÁ¤ÇÏ´Â °Ë»çÀÇ ÇϳªÀÌ´Ù. ÇǰËÇ÷Àå¿¡ Ä®½·À̿°ú Á¶Á÷Æ®·Òº¸ÇÃ¶ó½ºÆ¾(Á¦III ÀÀ°íÀÎÀÚ)À» °¡ÇØ, ¼¶À¯¼Ò°¡ ³ªÅ¸³¯ ¶§±îÁöÀÇ ½Ã°£À¸ ÃøÁ¤ÇÑ´Ù. |
||
| CT | calcitonin; calf testis; cardiac tamponade; cardiothoracic [ratio]; carotid tracing; carpal tunnel; ... |
|---|---|
| PTT | partial thromboplastin time; particle transport time; posterior tibial tendon (transfer); prothrombi... |
| AGC | Automatic Gain Control |
| AGC | absolute granulocyte count; automatic gain control |
| TCG | time-compensated gain |
| AGC | Automatic Gain Control |
|---|---|
| Control | control |
| control group | control |
| ADG | Average daily gain |
| BWG | Body weight gain |
| time-varied gain control | In ultrasonography, an increase in receiver gain with time to compensate for loss in echo amplitude with depth, usually due to attenuation. Synonym: attenuation compensation, depth compensation, time compensation gain, time-compensated gain, time-varied gain control, time-varied gain. (05 Mar 2000) |
|---|---|
| time-compensated gain | In ultrasonography, an increase in receiver gain with time to compensate for loss in echo amplitude with depth, usually due to attenuation. Synonym: attenuation compensation, depth compensation, time compensation gain, time-compensated gain, time-varied gain control, time-varied gain. (05 Mar 2000) |
| time compensation gain | In ultrasonography, an increase in receiver gain with time to compensate for loss in echo amplitude with depth, usually due to attenuation. Synonym: attenuation compensation, depth compensation, time compensation gain, time-compensated gain, time-varied gain control, time-varied gain. (05 Mar 2000) |
| time-gain compensation | In ultrasonography, an increase in receiver gain with time to compensate for loss in echo amplitude with depth, usually due to attenuation. Synonym: attenuation compensation, depth compensation, time compensation gain, time-compensated gain, time-varied gain control, time-varied gain. (05 Mar 2000) |
| time-varied gain | In ultrasonography, an increase in receiver gain with time to compensate for loss in echo amplitude with depth, usually due to attenuation. Synonym: attenuation compensation, depth compensation, time compensation gain, time-compensated gain, time-varied gain control, time-varied gain. (05 Mar 2000) |
| gain | <physics> (Amplification) Increase in a signal transmitted from one point to another through an amplifier. (09 Oct 1997) |
| weight gain | Increase in body weight over existing weight. (12 Dec 1998) |
| primary gain | Interpersonal, social, or financial advantages from the conversion of emotional stress directly into demonstrably organic illnesses (e.g., hysterical blindness or paralysis). Compare: secondary gain. (05 Mar 2000) |
| secondary gain | Interpersonal or social advantages (e.g., assistance, attention, sympathy) gained indirectly from organic illness. Compare: primary gain. (05 Mar 2000) |
| activated clotting time | The most common test used for coagulation time in cardiovascular surgery. (05 Mar 2000) |
| activated partial thromboplastin time | The time needed for plasma to form a fibrin clot following the addition of calcium and a phospholipid reagent; used to evaluate the intrinsic clotting system. (05 Mar 2000) |
| A-H conduction time | Forward conduction of the cardiac impulse from atria to ventricles via the A-V node or any bypass tract, represented in the electrocardiogram by the P-R interval. P-H conduction time is from the onset of the P wave to the first high frequency component of the His bundle electrogram (normally 119 ± 38 msec); A-H conduction time is from the onset of the first high frequency component of the atrial electrogram to the first high frequency component of the His bundle electrogram (normally 92 ± 38 msec); P-A conduction time is from the onset of the P wave to the onset of the atrial electrogram (normally 27 ± 18 msec). (05 Mar 2000) |
| association time | Time elasping between a stimulus and the verbalised response to it. (05 Mar 2000) |
| biologic time | The concept that our appreciation of time varies with age and is governed by the neural organization of the individual; it obeys a logarithmic rather than an arithmetic law. (05 Mar 2000) |
| bleeding time | <haematology> A test which measures the time it takes for small blood vessels to close off and bleeding to stop. Abnormal results can be seen in those with congenital or acquired platelet function disorders or thrombocytopenia. (27 Sep 1997) |
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|