| ¿µ¹® | ectopic pregnancy | ÇÑ±Û | ÀÚ±Ã¿Ü ÀӽŠ|
|---|---|---|---|
| ¼³¸í | »êºÎÀΰú ¿µ¿ª¿¡¼ °¡Àå ºó¹øÇÑ ÀÀ±Þ º´À¸·Î, ±× ¹ß»ý ºóµµ´Â ¸Å³â Áõ°¡ÇÏ´Â Ãß¼¼ÀÌ´Ù. ÀÚ±Ã¿Ü ÀÓ½ÅÀº ¼öÁ¤¶õÀÌ Á¤»óÀûÀÎ À§Ä¡ÀÎ ÀڱøöÅëÀÇ ³»°¿¡ Âø»óµÇÁö ¾Ê°í ´Ù¸¥ °÷, Áï ³¼Ò¿¡¼ ³ª¿Â ³ÀÚ¸¦ ÀڱñîÁö ¿î¹ÝÇÏ´Â Àڱðü, ³ÀÚ¸¦ »ý»êÇÏ´Â ³¼Ò, ÀÚ±ÃÀ» ÁöÁöÇÏ´Â ¿©·¯ Àδë, º¹°, ÀÚ±ÃÀÇ ÀÔ±¸¿¡ ÇØ´çÇÏ´Â ÀڱðæºÎ µî¿¡ Âø»óµÇ´Â ÀÓ½ÅÀ» ¸»ÇÑ´Ù. Âø»óÇÏ´Â ºÎÀ§¿¡ µû¶ó Àڱðü ÀÓ½Å, Àڱøñ°ü ÀÓ½Å, ³¼Ò ÀÓ½Å, º¹¸·ÀÓ½Å, Àδ볻 ÀӽеîÀ¸·Î ³ª´µ¸ç, °¡Àå ÈçÇÑ ÀÚ±Ã¿Ü ÀÓ½ÅÀº Àڱðü ÀÓ½ÅÀÌ´Ù. ÀÚ±Ã¿Ü ÀÓ½ÅÀÌ Áõ°¡ÇÏ´Â ÀÌÀ¯·Î´Â ¿ì¼± ºÒ°áÇÑ ¼ºÀû Á¢ÃË¿¡ ÀÇÇØ ÀüÆÄµÇ´Â ±Þ¼º ³°ü¿°ÀÇ Áõ°¡¸¦ »ý°¢ÇÒ ¼ö ÀÖ´Ù. ½ÇÁ¦ ±Þ¼º ³°ü¿°À» ¾Î¾Ò´ø ¿©¼ºÀº ±× ´ÙÀ½ Àӽſ¡¼ ÀÚ±Ã¿Ü ÀÓ½ÅÀÌ µÉ È®·üÀÌ Á¤»óÀο¡ ºñÇÏ¿© 7¹è³ª ³ôÀº °ÍÀ¸·Î ¾Ë·ÁÁ® ÀÖ´Ù. ¶ÇÇÑ Àڱó» ÇÇÀÓÀåÄ¡¸¦ »ç¿ëÇÏ´Â ¿©¼º¿¡¼µµ Á¤»óÀκ¸´Ù ³ôÀº À²ÀÇ ÀÚ±Ã¿Ü ÀÓ½ÅÀÌ º¸°íµÇ¾ú´Ù. ÀÚ±Ã¿Ü ÀÓ½ÅÀÌ µÇ¸é ¹Ýµå½Ã ´Ù¾çÇÑ ÇüÅÂÀÇ ÇϺ¹ºÎ µ¿ÅëÀ» ³ªÅ¸³½´Ù. ´ëºÎºÐ ÃÖÁ¾ ¿ù°æÀÏÀ» ±âÁØÀ¸·Î 4ÁÖÂë ÈĺÎÅÍ ºÎÁ¤±â ÁúÃâÇ÷À» º¸ÀδÙ. ¶Ç °ú¹Ý¼öÀÇ È¯ÀÚ¿¡¼ À¯¹æÅëÀ̳ª ¸Ö¹Ì µîÀÌ ³ªÅ¸³ª±âµµ Çϳª, ü¿Â »ó½ÂÀº µå¹°´Ù. ±×·¯³ª ºü¸¥¸ÆÀº ÈçÈ÷ º¸ÀÌ´Â Áõ»óÀÌ´Ù. ÀÚ±Ã¿Ü ÀÓ½ÅÀÇ ¹®Á¦Á¡Àº Á¡Á¡ ÀÚ¶õ žƷΠÀÎÇØ¼ ÀÚ±Ã¿Ü ÀÓ½ÅÀÌ µÈ ºÎÀ§(ƯÈ÷ Àڱðü)°¡ ±×°ÍÀÇ Å©±â¸¦ °ßµðÁö ¸øÇؼ ÆÄ¿µÇ´Â °ÍÀÌ´Ù. ±×·¸°Ô µÇ¸é ¸¹Àº ¾çÀÇ Çǰ¡ ÇѲ¨¹ø¿¡ ÃâÇ÷ÀÌ µÇ¾î »ý¸íÀ» ÀÒÀ» ¼öµµ ÀÖ´Ù. ´ëºÎºÐÀÇ ÀÚ±Ã¿Ü ÀÓ½ÅÀº ÇöÀçÀÇ ¹ß´ÞµÈ Áø´Ü¹æ¹ýÀ¸·Î ºü¸£°í Á¤È®ÇÏ°Ô Áø´ÜÇÒ ¼ö ÀÖ´Ù. Áï Á÷Àå°ú ÀڱûçÀÌ¿¡ Á¸ÀçÇÏ´Â º¹°ÀÇ ÀϺκÐÀÎ ¸·ÈùÁÖ¸Ó´Ï(º¹° Áß¿¡¼ °¡Àå ³·Àº ºÎºÐ¿¡ Á¸ÀçÇÏ¿© º¹°³»ÀÇ ÃâÇ÷À̳ª ±âŸÀÇ ¾×ü´Â À̺κп¡ ¸ðÀδÙ)õÀÚ¼ú·Î 0.5mmÀÌ»óÀÇ ºñÀÀÇ÷¼º Ç÷¾×ÀÇ ÈíÀÔÀÌ µÉ °æ¿ì¿¡ ÀÚ±Ã¿Ü ÀÓ½ÅÀÇ ÆÄ¿·Î ÀÎÇÑ ÃâÇ÷ÀÓÀ» ¾Ë ¼ö°¡ ÀÖ°í, ÃÊÀ½ÆÄ ¿µ»ó¹ý¿¡ ÀÇÇÑ Áø´Ü, ÃÖ±ÙÀÇ ¸é¿ª ÈÇÐÀû È£¸£¸ó ÃøÁ¤¹ý°ú º¹°°æ °Ë»ç¹ý, ¶ÇÇÑ Àڱ󻸷 Á¶Á÷°Ë»ç µîÀ¸·Î½á Áø´ÜÇÒ ¼ö ÀÖ´Ù. |
||
| ¿µ¹® | pacemaker | ÇÑ±Û | ±æÀâÀÌ, ½ÉÀ屿ÀâÀÌ |
|---|---|---|---|
| ¼³¸í | ¿ì½É¹æ°ú »ó´ëÁ¤¸ÆÀÇ ¿¬Á¢ºÎ¿¡ Àִ Ưº°ÇÑ ½Å°æÁ¶Á÷¿Í µ¿¹æ°áÀý¿¡ ÀÇÇÑ ½É¹æ¼öÃàÀÌ ¹æ½Ç°áÀý·Î Àü´ÞµÇ¸é ½É½ÇÀÇ ¼öÃàÀÌ ½ÃÀ۵ȴÙ. ½É¹æ-¹æ½Ç°áÀý-½É½Ç¿¡¼ ¹ß»ýÇÏ´Â À̼Ҽº ¶Ç´Â ÀáÀ缺 ±æÀâÀÌ´Â ºñÁ¤»óÀû ½ÉÀå±â´É¿¡¼ ³ªÅ¸³ª´Â ¼öÃàÀÇ ¿øÀÎÀÌ µÇ±âµµ ÇÑ´Ù. ½ÉÀå ±æÀâÀ̶õ ½ÉÀå±ÙÀ°À» Àü±â·Î ÀÚ±ØÇÏ¿© ½ÉÇÑ ´À¸°¸Æ¿¡¼ ½ÉÀå¹Úµ¿·üÀ» Áõ°¡½Ã۴µ¥ ¾²ÀÌ´Â Àü±âÀû ÀåÄ¡. ½ÉÀåÀÌ »ý¸í À¯Áö¿¡ ÇÊ¿äÇÑ ÃÖ¼ÒÇÑÀÇ ¼Óµµ·Îµµ ÀÚ¹ßÀûÀÎ ¼öÃàÀ» ÇÏÁö ¸øÇÒ ¶§ ½É¹ÚÁ¶À²±â°¡ ÀÏÁ¤ÇÏ°Ô °íÁ¤µÈ ¼ÓµµÀÇ Àü±âÀû ÀÚ±ØÀ» ÀϽÃÀû ¶Ç´Â ¿µ±¸ÀûÀ¸·Î º¸³¾ ¼ö ÀÖ´Ù. |
||
| ¿µ¹® | pacemaker | ÇÑ±Û | ¹Úµ¿Á¶À²±â |
|---|---|---|---|
| ¼³¸í | ¿ì½É¹æ°ú »ó´ëÁ¤¸ÆÀÇ ¿¬Á¢ºÎ¿¡ Àִ Ưº°ÇÑ ½Å°æÁ¶Á÷¿Í µ¿¹æ°áÀý¿¡ ÀÇÇÑ ½É¹æ¼öÃàÀÌ ¹æ½Ç°áÀý·Î Àü´ÞµÇ¸é ½É½ÇÀÇ ¼öÃàÀÌ ½ÃÀ۵ȴÙ. ½É¹æ-¹æ½Ç°áÀý-½É½Ç¿¡¼ ¹ß»ýÇÏ´Â À̼Ҽº ¶Ç´Â ÀáÀ缺 ±æÀâÀÌ´Â ºñÁ¤»óÀû ½É±â´É¿¡¼ ³ªÅ¸³ª´Â ¼öÃàÀÇ ¿øÀÎÀÌ µÇ±âµµ ÇÑ´Ù. ½ÉÀå ±æÀâÀ̶õ ½ÉÀå±ÙÀ°À» Àü±â·Î ÀÚ±ØÇÏ¿© ½ÉÇÑ ´À¸°¸Æ¿¡¼ ½ÉÀå¹Úµ¿·üÀ» Áõ°¡½Ã۴µ¥ ¾²ÀÌ´Â Àü±âÀû ÀåÄ¡. ½ÉÀåÀÌ »ý¸í À¯Áö¿¡ ÇÊ¿äÇÑ ÃÖ¼ÒÇÑÀÇ ¼Óµµ·Îµµ ÀÚ¹ßÀûÀÎ ¼öÃàÀ» ÇÏÁö ¸øÇÒ ¶§ ½É¹ÚÁ¶À²±â°¡ ÀÏÁ¤ÇÏ°Ô °íÁ¤µÈ ¼ÓµµÀÇ Àü±âÀû ÀÚ±ØÀ» ÀϽÃÀû ¶Ç´Â ¿µ±¸ÀûÀ¸·Î º¸³¾ ¼ö ÀÖ´Ù. |
||
| ¿µ¹® | pacemaker(of heart) | ÇÑ±Û | ½ÉÀå¹Úµ¿±â |
|---|---|---|---|
| ¼³¸í | ½ÉÀåÀÇ Àü±âÀû ÀÚ±ØÀÌ º´ÀûÀÎ »óÅ·Π¹ß»ýÇÏÁö ¾Ê°Å³ª, ȤÀº ½É½Ç·Î Àß ÀüÇØÁöÁö ¾ÊÀ» ¶§ »ç¿ëÇÑ´Ù. ÀϽÃÀû ½ÉÀå¹Úµ¿±â¿Í ¿µ±¸Àû ½ÉÀå¹Úµ¿±â°¡ ÀÖÀ¸¸ç, °¢±â ¾²ÀÌ´Â ¿ëµµ´Â º´¿¡ µû¶ó ´Ù¸£´Ù. ¿äÁò¿¡ ³ª¿À´Â ½ÉÀå ¹Úµ¿±â´Â °ÇÀüÁöÀÇ ¼ö¸íµµ ¹Ý¿µ±¸ÀûÀ̸ç, ¹Û¿¡¼ Á¶Á¤ÇÒ ¼ö ÀÖ°í, ¿îµ¿À̳ª ½ºÆ®·¹½º »óȲ¿¡ ´ëÇÑ ½ÉÀåÀÇ ºü¸¥ ¿îµ¿¿¡µµ Àß ÀûÀÀÇÒ ¼ö ÀÖµµ·Ï ¸¸µé¾îÁ® ÀÖ´Ù. |
||
| ECG | Electro-Cardio-Graphy(-Gram); ½ÉÀüµµ = EKG 1. Conducting System Structu... |
|---|---|
| VEA | ventricular ectopic activity; ventricular ectopic arrhythmia; viral envelope antigen |
| HCG, hCG | Human Chorionic Gonadotropin; »ç¶÷À¶¸ð¼º¼º¼±ÀÚ±ØÈ£¸£¸ó 1. Placental Glycoprotein Hormone &nbs... |
| VEB | Ventricular Ectopic Beat = PVC |
| AE | above-elbow [amputation]; acrodermatitis enteropathica; activation energy; adult erythrocyte; advers... |
| PMT | Pacemaker-Mediated Tachycardia |
|---|---|
| EAT | Ectopic atrial tachycardia |
| EPs | Ectopic pregnancies |
| EP | Ectopic pregnancy |
| VEA | Ventricular ectopic activity |
| ectopic pacemaker | Any pacemaker other than the sinus node. (05 Mar 2000) |
|---|
| artificial pacemaker | Any device that substitutes for the normal pacemaker and controls the rhythm of the organ; especially an electronic cardiac pacemaker, which may be implanted in the chest, with electrodes attached to the external cardiac surface, or passed through the venous circulation into the right side of the heart (pervenous pacemaker). (05 Mar 2000) |
|---|---|
| cardiac pacemaker | An electrical device which delivers a small stimulant shock to the heart to effect cardiac contraction at a pre-determined rate. Many of today's pacemakers have two main components: the electrodes and the transducer (pulse generator). The electrodes are wires which are placed into the circulatory system and make physical contact with the heart muscle. A small electrical discharge from the pacemaker electrode stimulates the muscular wall of the heart to contract, thus pumping blood in an organised fashion. The transducer is a small device, usually implanted under the skin, that generates the electrical discharge at a pre-determined frequency. Transducers can monitor your heart's rate of contraction and deliver an electrical shock only when the heart is going too slow. (27 Sep 1997) |
| pacemaker | 1. <apparatus, physiology> An object or substance that influences the rate at which a certain phenomenon occurs, often used alone to indicate the natural cardiac pacemaker or an artificial cardiac pacemaker. 2. <biochemistry> A substance whose rate of reaction sets the pace for a series of interrelated reactions. (24 Mar 1998) |
| pacemaker, artificial | A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). (12 Dec 1998) |
| pacemaker failure | Failure of an artificial pacemaker to generate or deliver effective stimuli to the myocardium. (05 Mar 2000) |
| pacemaker output | Electrical energy delivered into a standard load (500 ohms resistance). (05 Mar 2000) |
| pacemaker potential | The voltage inscribed by impulses from an artificial electronic pacemaker. (05 Mar 2000) |
| pacemaker sensitivity | The minimum cardiac activity required to consistently trigger a pulse generator. (05 Mar 2000) |
| pacemaker syndrome | <syndrome> The occurrence of symptoms relating to the loss of atrial-ventricular synchrony in ventricularly paced patients, or symptoms caused by inadequate timing of atrial and ventricular contractions in paced patients. (05 Mar 2000) |
| refractory period of electronic pacemaker | The time required to restore full sensitivity after detecting cardiac activity or delivering a pacing impulse. (05 Mar 2000) |
| pervenous pacemaker | An artificial pacemaker passed through the venous circulation into the right side of the heart. (05 Mar 2000) |
| runaway pacemaker | Rapid heart rates over 140/min caused by electronic circuit instability in an implanted pulse generator. (05 Mar 2000) |
| wandering pacemaker | A disturbance of the normal cardiac rhythm in which the site of the controlling pacemaker shifts from beat to beat, usually between the sinus and A-V nodes, often with gradual sequential changes in P waves between upright and inverted in a given ECG lead. Synonym: shifting pacemaker. (05 Mar 2000) |
| shifting pacemaker | A disturbance of the normal cardiac rhythm in which the site of the controlling pacemaker shifts from beat to beat, usually between the sinus and A-V nodes, often with gradual sequential changes in P waves between upright and inverted in a given ECG lead. Synonym: shifting pacemaker. (05 Mar 2000) |
| subsidiary atrial pacemaker | Secondary source for rhythmic control of the heart, available for controlling cardiac activity if the sinoatrial pacemaker fails; located within the crista terminalis and atrial free wall near the inferior vena cava. (05 Mar 2000) |
| ectopic pacemaker |
any biological cardiac pacemaker other than the sinus node; under normal conditions it is not active.
Ãâó: www.mercksource.com/pp/us/cns/cns_hl_dorlands.jspz...
|
|---|
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|
Á¦Ç°¸í |
ÆÇ¸Å»ç |
º¸ÇèÄÚµå | ¼ººÐ/ÇÔ·® | ±¸ºÐ/º¸Çè±Þ¿© |
|---|