¼±Åà - È­»ìǥŰ/¿£ÅÍŰ ´Ý±â - ESC

 
"A-V sequential pacemaker"¿¡ ´ëÇÑ °Ë»ö °á°úÀÔ´Ï´Ù. °Ë»ö °á°ú º¸´Â µµÁß¿¡ Tab ۸¦ ´©¸£½Ã¸é °Ë»ö âÀÌ ¼±Åõ˴ϴÙ.
¾Ë±â½¬¿î ÀÇÇпë¾îÇ®ÀÌÁý, ¼­¿ïÀÇ´ë ±³¼ö ÁöÁ¦±Ù, °í·ÁÀÇÇÐ ÃâÆÇ À¯»ç °Ë»ö °á°ú : 3 ÆäÀÌÁö: 1
¿µ¹® pacemaker ÇÑ±Û ±æÀâÀÌ, ½ÉÀ屿ÀâÀÌ
¼³¸í   
  ¿ì½É¹æ°ú »ó´ëÁ¤¸ÆÀÇ ¿¬Á¢ºÎ¿¡ Àִ Ưº°ÇÑ ½Å°æÁ¶Á÷¿Í µ¿¹æ°áÀý¿¡ ÀÇÇÑ ½É¹æ¼öÃàÀÌ ¹æ½Ç°áÀý·Î Àü´ÞµÇ¸é ½É½ÇÀÇ ¼öÃàÀÌ ½ÃÀ۵ȴÙ. ½É¹æ-¹æ½Ç°áÀý-½É½Ç¿¡¼­ ¹ß»ýÇϴ À̼Ҽº ¶Ç´Â ÀáÀ缺 ±æÀâÀ̴ ºñÁ¤»óÀû ½ÉÀå±â´É¿¡¼­ ³ªÅ¸³ª´Â ¼öÃàÀÇ ¿øÀÎÀÌ µÇ±âµµ ÇÑ´Ù. ½ÉÀå ±æÀâÀ̶õ ½ÉÀå±ÙÀ°À» Àü±â·Î ÀÚ±ØÇÏ¿© ½ÉÇÑ ´À¸°¸Æ¿¡¼­ ½ÉÀå¹Úµ¿·üÀ» Áõ°¡½Ã۴µ¥ ¾²À̴ Àü±âÀû ÀåÄ¡. ½ÉÀåÀÌ »ý¸í À¯Áö¿¡ ÇÊ¿äÇÑ ÃÖ¼ÒÇÑÀÇ ¼Óµµ·Îµµ ÀÚ¹ßÀûÀΠ¼öÃàÀ» ÇÏÁö ¸øÇÒ ¶§ ½É¹ÚÁ¶À²±â°¡ ÀÏÁ¤ÇϰԠ°íÁ¤µÈ ¼ÓµµÀÇ Àü±âÀû ÀÚ±ØÀ» ÀϽÃÀû ¶Ç´Â ¿µ±¸ÀûÀ¸·Î º¸³¾ ¼ö ÀÖ´Ù. 
¿µ¹® pacemaker ÇÑ±Û ¹Úµ¿Á¶À²±â
¼³¸í   
  ¿ì½É¹æ°ú »ó´ëÁ¤¸ÆÀÇ ¿¬Á¢ºÎ¿¡ Àִ Ưº°ÇÑ ½Å°æÁ¶Á÷¿Í µ¿¹æ°áÀý¿¡ ÀÇÇÑ ½É¹æ¼öÃàÀÌ ¹æ½Ç°áÀý·Î Àü´ÞµÇ¸é ½É½ÇÀÇ ¼öÃàÀÌ ½ÃÀ۵ȴÙ. ½É¹æ-¹æ½Ç°áÀý-½É½Ç¿¡¼­ ¹ß»ýÇϴ À̼Ҽº ¶Ç´Â ÀáÀ缺 ±æÀâÀ̴ ºñÁ¤»óÀû ½É±â´É¿¡¼­ ³ªÅ¸³ª´Â ¼öÃàÀÇ ¿øÀÎÀÌ µÇ±âµµ ÇÑ´Ù. ½ÉÀå ±æÀâÀ̶õ ½ÉÀå±ÙÀ°À» Àü±â·Î ÀÚ±ØÇÏ¿© ½ÉÇÑ ´À¸°¸Æ¿¡¼­ ½ÉÀå¹Úµ¿·üÀ» Áõ°¡½Ã۴µ¥ ¾²À̴ Àü±âÀû ÀåÄ¡. ½ÉÀåÀÌ »ý¸í À¯Áö¿¡ ÇÊ¿äÇÑ ÃÖ¼ÒÇÑÀÇ ¼Óµµ·Îµµ ÀÚ¹ßÀûÀΠ¼öÃàÀ» ÇÏÁö ¸øÇÒ ¶§ ½É¹ÚÁ¶À²±â°¡ ÀÏÁ¤ÇϰԠ°íÁ¤µÈ ¼ÓµµÀÇ Àü±âÀû ÀÚ±ØÀ» ÀϽÃÀû ¶Ç´Â ¿µ±¸ÀûÀ¸·Î º¸³¾ ¼ö ÀÖ´Ù. 
¿µ¹® pacemaker(of heart) ÇÑ±Û ½ÉÀå¹Úµ¿±â
¼³¸í   
  ½ÉÀåÀÇ Àü±âÀû ÀÚ±ØÀÌ º´ÀûÀΠ»óÅ·Π¹ß»ýÇÏÁö ¾Ê°Å³ª, È¤Àº ½É½Ç·Î Àß ÀüÇØÁöÁö ¾ÊÀ» ¶§ »ç¿ëÇÑ´Ù. ÀϽÃÀû ½ÉÀå¹Úµ¿±â¿Í ¿µ±¸Àû ½ÉÀå¹Úµ¿±â°¡ ÀÖÀ¸¸ç, °¢±â ¾²À̴ ¿ëµµ´Â º´¿¡ µû¶ó ´Ù¸£´Ù.
  
  ¿äÁò¿¡ ³ª¿À´Â ½ÉÀå ¹Úµ¿±â´Â °ÇÀüÁöÀÇ ¼ö¸íµµ ¹Ý¿µ±¸ÀûÀ̸ç, ¹Û¿¡¼­ Á¶Á¤ÇÒ ¼ö ÀÖ°í, ¿îµ¿À̳ª ½ºÆ®·¹½º »óȲ¿¡ ´ëÇÑ ½ÉÀåÀÇ ºü¸¥ ¿îµ¿¿¡µµ Àß ÀûÀÀÇÒ ¼ö ÀÖµµ·Ï ¸¸µé¾îÁ® ÀÖ´Ù.
´ëÇÑÀÇÇù ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 15 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • atrioventricular sequential pacemaker
    ¹æ½Ç¼øÂ÷Çü¹Úµ¿Á¶À²±â
  • sequential analysis
    ¼øÂ÷ÀûºÐ¼®, ÀϷúм®
  • sequential chemoradiation
    ¼øÂ÷ÀûÈ­Çйæ»ç¼±Á¶»ç
  • sequential design
    ¼øÂ÷°èȹ¹ý
  • sequential model
    ¼øÂ÷¸ðµ¨
  • sequential multislice acquisition
    ¼øÂ÷Àû´ÙÀýÆíȹµæ
  • sequential segmental irradiation
    ¿¬¼ÓÁ¶»ç¿ªÁ¶»ç
  • atrial synchronous pacemaker
    ½É¹æµ¿Á¶Çü¹Úµ¿Á¶À²±â
  • circadian pacemaker
    ÇÏ·çÁÖ±âÁ¶Á¤ÀÚ
  • cardiac pacemaker
    ½ÉÀå¹Úµ¿Á¶À²±â
  • demand pacemaker
    ¼ö¿ä¹Úµ¿Á¶À²±â
  • ectopic pacemaker
    µý°÷¹Úµ¿Á¶À²±â, À̼Ҽº½ÉÀå¹Úµ¿Á¶À²±â
  • external pacemaker
    ü¿Ü¹Úµ¿Á¶À²±â
  • fixed rate pacemaker
    °íÁ¤¼Óµµ¹Úµ¿Á¶À²±â
  • implanted pacemaker
    À̽Ĺڵ¿Á¶À²±â
´ëÇÑÀÇÇù Çʼö ÀÇÇпë¾îÁý »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 2 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • pacemaker
    ±æÀâÀÌ, ¹Úµ¿Á¶À²±â, ¹ßµ¿±â
  • cardiac pacemaker
    ½ÉÀå¹Úµ¿Á¶À²±â
¿¾ ´ëÇÑÀÇÇù ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 15 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • atrioventricular sequential pacemaker
    ¹æ½Ç¼øÂ÷Çü¹Úµ¿Á¶À²±â
  • sequential analysis
    ¼øÂ÷ÀûºÐ¼®
  • sequential multislice acquisition
    ¼øÂ÷Àû´ÙÀýÆíȹµæ
  • sequential design
    ¼øÂ÷Àû°èȹ¹ý
  • sequential segmental irradiation
    ¿¬¼ÓÁ¶»ç¿ªÁ¶»ç
  • sequential model
    ¼øÂ÷¸ðµ¨
  • atrial synchronous pacemaker
    ½É¹æµ¿Á¶Çü¹Úµ¿Á¶À²±â
  • cardiac pacemaker
    ½ÉÀå¹Úµ¿Á¶À²±â
  • circadian pacemaker
    ÀÏÁÖ±âÁ¶Á¤ÀÚ
  • demand pacemaker
    ¼ö¿ä¹Úµ¿Á¶À²±â
  • ectopic pacemaker
    À̼Ҽº½ÉÀå¹Úµ¿Á¶À²±â, µý°÷¹Úµ¿Á¶À²±â
  • external pacemaker
    ü¿Ü¹Úµ¿Á¶À²±â
  • fixed rate pacemaker
    °íÁ¤¼Óµµ¹Úµ¿Á¶À²±â
  • idioventricular pacemaker
    ½É½Ç°íÀ¯¹Úµ¿Á¶Àý±â
  • implantable pacemaker
    À̽Ĺڵ¿Á¶À²±â
¿¾ ´ëÇÑÀÇÇù 2 ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 1 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • A-V sequential pacemaker
    ¹æ½Ç¼øÂ÷Çü ½É¹ÚÁ¶À²±â.
¿¾ ´ëÇÑÀÇÇù 2 ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 5 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • primordium of sequential muscles
    ¿¬¼Ó±ÙÀ°¿ø±â
  • artificial pacemaker
    ÀΰøÆäÀ̽º¸ÞÀÌÄ¿.
  • artificial pacemaker
    Àΰø½É¹ÚÁ¶À²±â
  • idioventricular pacemaker
    Àڹ߽Ǽº Á¶Á¤±â(í»Û¡ãøàõðàïÚÐï), ½É½Ç°íÀ¯¹Úµ¿ Á¶Àý±â.
  • implantable pacemaker
    À̽ļº ½É¹Úµ¿ Á¶Àý±â.
¿¾ ´ëÇÑÀÇÇù 3 ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 15 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • primordium of sequential muscles
    ¿¬¼Ó±ÙÀ°¿ø±â
  • sequential design
    ÃàÂ÷ °èȹ¹ý.
  • sequential induction
    ¼øÂ÷Àû À¯µµ(ËàÌ¤Ëø ËôËÀ).
  • sequential model
    ¼øÂ÷¸ðµ¨.
  • sequential multislice acquisition
    ¼øÂ÷Àû ´ÙÀýÆí ȹµæ
  • sequential segmental irradiation
    ¿¬¼ÓÁ¶»ç¿ªºÐÇÒ¹æ»ç¼±Á¶»ç
  • sequential test
    ÃàÂ÷ °ËÁ¤.
  • artificial pacemaker
    ÀΰøÆäÀ̽º¸ÞÀÌÄ¿.
  • artificial pacemaker
    Àΰø½É¹ÚÁ¶À²±â
  • atrial synchronized pacemaker
    ½É¹æµ¿Á¶Çü ½É¹ÚÁ¶À²±â.
  • cardiac pacemaker
    ½É¹ÚÁ¶À²±â, ½É¹ÚÁ¶Á¤±â(¡­ðàïÚÐï).
  • cardiac pacemaker
    ½É¹ÚÁ¶À²±â(ãýÚÏðàëÏÐï),½É¹ÚÁ¶Á¤±â(-ðàïÚÐï).
  • cardiac pacemaker
    ½É¹ÚÁ¶À²±â, ½É¹ÚÁ¶Á¤±â
  • cardiac pacemaker
    ½É¹Ú Á¶À²±â(ãýÚÑðàëÏÐï)
  • circadian pacemaker
    ÀÏÁÖ±â Á¶Á¤±â(ìíñÎÑ¢ ðàïÚѦ)
´ëÇÑ»ýÈ­ÇкÐÀÚ»ý¹°ÇÐȸ ¿ë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 4 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • pacemaker enzyme
    "¼ÓµµÁ¶Á¤È¿¼Ò(áÜÓøðàïÚý£áÈ), ÆäÀ̽º¸ÞÀÌÄ¿ È¿¼Ò(ý£áÈ)"
  • sequential mechanism
    ¼øÂ÷±âÀü(â÷ó­Ñ¦ï®)
  • sequential model
    ¼øÂ÷(â÷ó­)¸ðµ¨
  • sequential reaction
    ¼øÂ÷¹ÝÀÀ(â÷ó­Úãëë)
KI ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 3 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • pacemaker
    ½É¹ÚÁ¶À²±â, ÇâµµÀâÀÌ
  • sequential analysis
    ¼øÂ÷ÀûºÐ¼®
  • sequential multislice acquisition
    ¼øÂ÷Àû´ÙÀýÆíȹµæ
KMLE ÀÇÇоà¾î »çÀü À¯»ç °Ë»ö °á°ú : 5 ÆäÀÌÁö: 1
ECG Electro-Cardio-Graphy(-Gram); ½ÉÀüµµ
   = EKG
  1. Conducting System Structu...
SMA sequential multiple analysis or analyzer; sequential multichannel autoanalyzer; simultaneous multich...
DVI deep venous insufficiency; diastolic velocity integral; digital vascular imaging; Doppler velocity i...
BSAM basic sequential access method
SAV sequential atrioventricular [pacing]
KMLE ÀÚµ¿ÃßÃâ ÀÇÇоà¾î »çÀü À¯»ç °Ë»ö °á°ú : 4 ÆäÀÌÁö: 1
PMT Pacemaker-Mediated Tachycardia
SCD Sequential Compression Devices
SOFA Sequential Organ Failure Assessment
SPRT Sequential Probability Ratio Test
°æºÏ´ë Ä¡°ú´ëÇÐ ±¸°­³»°ú ±³½Ç »çÀü À¯»ç °Ë»ö °á°ú : 13 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
    ¼³¸í
  • sequential analysis
    ¼øÂ÷Àû ºÐ¼®
  • artificial pacemaker
    Àΰø ½É¹Ú Á¶À²±â
  • asynchronous pacemaker
    ºñµ¿±â¼º ½É¹ÚÁ¶À²±â
    ½ÉÀå¿¡ À̽ÄÇÑ Á¶À²±â·Î¼­ ½É¹æ°ú´Â °ü°è¾øÀÌ ½É½Ç À²µ¿À» À¯¹ßÇÏ´Â °ÍÀ̸ç, º¸Åë ÀÏÁ¤ÇÑ ºóµµ·Î ½É½ÇÀ» ÀÚ±ØÇϵµ·Ï µÇ¾î ÀÖ´Ù.
  • cardiac pacemaker
    ½É¹Ú Á¶À²±â, ½É¹Ú Á¶Á¤±â, Àΰø ½É¹Ú Á¶À²±â
    Àü±â±Ø Àڱؿ¡ ÀÇÇÏ¿© ½É±ÙÀÇ ¼öÃàÀ» ÀÏÁ¤ÇÑ À²·Î ÀÛµ¿½ÃŰ´Â ÀåÄ¡·Î¼­ ƯÈ÷ ½ÉÀå ºÒ·ÏÀ̳ª µ¿¹æ °áÀýÀÌ Á¤»óÀûÀÎ ÀÛµ¿ÀÌ »ó½ÇµÇ¾úÀ» ¶§ »ç¿ëµÈ´Ù. ü¿Ü¿¡ ºÎÂø½Ã۵çÁö ü³»¿¡ ¸Å½ÄÇÏ¿© ÀåÄ¡ÇÑ´Ù.
  • circadian pacemaker
    ÀÏÁÖ±â Á¶Á¤±â
  • demand pacemaker
    ¼ö¿ä ½É¹Ú Á¶À²±â
  • ectopic pacemaker
    À̼Ҽº ½É¹Ú Á¶À²±â, À̼Ҽº ¹ßÈ­Á¡
    1. µ¿°áÀý ÀÌ¿ÜÀÇ ½É¹Ú Á¶À²±â. 2. Á¤»óÀûÀ¸·Î´Â ½É±ÙÀ̳ª His bundle°ú Purkinje ¼¶À¯°°Àº Àüµµ°è´Â
  • electric pacemaker
    Àü±â ½É¹Ú Á¶À²±â
  • external pacemaker
    ü¿Ü ½É¹ÚÁ¶À²±â
    ü¿Ü¿¡ ÀåÄ¡ÇÑ Àΰø ½É¹Ú Á¶À²±â·Î¼­ Ãâ·Â¼±À» µÕ±Ù ÈäºÎ Àü±Ø¿¡ ¿¬°áÇϵ簡, Á÷Á¢ ½ÉÀå¿¡ À̽ÄÇϵ簡 ¶Ç´Â Á¤¸Æ Ä«Å×Å͸¦ ÅëÇÏ¿© »ðÀÔÇÑ Àü±Ø¿¡ ¿¬°á½ÃŲ´Ù.
  • implanted pacemaker
    ¸Å½Ä ½É¹Ú Á¶À²±â
    ÇÇÇÏ Á¶Á÷¿¡ ¸Å½ÄÇÑ ½É¹Ú Á¶À²±â.
  • pacemaker
    ½É¹Ú º¸Á¶ Á¶Á¤±â, ½É¹Ú Á¶À²±â, ÇâµµÀâÀÌ
    ¾î¶² Çö»óÀÌ ÀϾ´Â À²µ¿¿¡ ¿µÇâÀ» ¹ÌÄ¡´Â ¹°Áú ¶Ç´Â ¹°Ã¼·Î¼­ ÈçÈ÷ ½É¹Ú Á¶À²±â¸¦ ¸»ÇÑ´Ù. »ýÈ­Çп¡ À־´Â ÀÏ·ÃÀÇ »ó°ü ¹ÝÀÀ °úÁ¤¿¡¼­ ¾î¶² ¹°ÁúÀÇ ¹ÝÀÀ ¼Óµµ°¡ ¿¬°ü ¹ÝÀÀ ÀüüÀÇ ¼Óµµ¸¦ °áÁ¤ÇÏ´Â ¹°Áú.
  • transthoracic pacemaker
    °æÈä ½É¹Ú Á¶À²±â
    È亮À» Åë°ú½ÃŲ ħÀ» ÅëÇÏ¿© µµÀÔÇÑ °æÇÇ Á¶À² ö»ç¼±À¸·Î ½ÉÀå°ú ¿¬°á½ÃŲ ¿ÜºÎ ½É¹Ú Á¶À²±â.
  • wandering pacemaker
    À¯ÁÖ ½É¹ÚÁ¶À²±â, À¯ÁÖ¼º ½É¹ÚÁ¶À²±â
    ½É¹Ú ¼ö¸¦ Á¶ÀýÇÏ´Â Ãæµ¿ÀÇ ±Ù¿øÀÌ µ¿¹æ°áÀýÀÇ ¸Ó¸® ºÎºÐÀ¸·ÎºÎÅÍ ÇϺΠ¶Ç´Â ½É¹æÀÇ ´Ù¸¥ °÷À¸·Î À̵¿ÇÏ´Â »óÅÂ.
CancerWEB ¿µ¿µ ÀÇÇлçÀü À¯»ç °Ë»ö °á°ú : 15 ÆäÀÌÁö: 1
contraceptives, oral, sequential Drugs administered orally and sequentially for contraceptive purposes.
(12 Dec 1998)
sequential Occurring in sequence.
(05 Mar 2000)
sequential analysis A statistical method that allows an experiment to be ended as soon as a result of desired precision is obtained.
(05 Mar 2000)
sequential hermaphrodite <biology, zoology> A type of hermaphrodite which starts out life as one sex and will either turn into a member of the other sex at a later point in life or will be capable of doing so if an appropriate condition arises (for example: the removal of all of the males in a population triggers the most dominant female to become a male).
(11 Jun 1998)
artificial pacemaker Any device that substitutes for the normal pacemaker and controls the rhythm of the organ; especially an electronic cardiac pacemaker, which may be implanted in the chest, with electrodes attached to the external cardiac surface, or passed through the venous circulation into the right side of the heart (pervenous pacemaker).
(05 Mar 2000)
cardiac pacemaker An electrical device which delivers a small stimulant shock to the heart to effect cardiac contraction at a pre-determined rate. Many of today's pacemakers have two main components: the electrodes and the transducer (pulse generator). The electrodes are wires which are placed into the circulatory system and make physical contact with the heart muscle. A small electrical discharge from the pacemaker electrode stimulates the muscular wall of the heart to contract, thus pumping blood in an organised fashion. The transducer is a small device, usually implanted under the skin, that generates the electrical discharge at a pre-determined frequency. Transducers can monitor your heart's rate of contraction and deliver an electrical shock only when the heart is going too slow.
(27 Sep 1997)
pacemaker 1. <apparatus, physiology> An object or substance that influences the rate at which a certain phenomenon occurs, often used alone to indicate the natural cardiac pacemaker or an artificial cardiac pacemaker.
2. <biochemistry> A substance whose rate of reaction sets the pace for a series of interrelated reactions.
(24 Mar 1998)
pacemaker, artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external).
(12 Dec 1998)
pacemaker failure Failure of an artificial pacemaker to generate or deliver effective stimuli to the myocardium.
(05 Mar 2000)
pacemaker output Electrical energy delivered into a standard load (500 ohms resistance).
(05 Mar 2000)
pacemaker potential The voltage inscribed by impulses from an artificial electronic pacemaker.
(05 Mar 2000)
pacemaker sensitivity The minimum cardiac activity required to consistently trigger a pulse generator.
(05 Mar 2000)
pacemaker syndrome <syndrome> The occurrence of symptoms relating to the loss of atrial-ventricular synchrony in ventricularly paced patients, or symptoms caused by inadequate timing of atrial and ventricular contractions in paced patients.
(05 Mar 2000)
refractory period of electronic pacemaker The time required to restore full sensitivity after detecting cardiac activity or delivering a pacing impulse.
(05 Mar 2000)
pervenous pacemaker An artificial pacemaker passed through the venous circulation into the right side of the heart.
(05 Mar 2000)
ÇÑ¿µ/¿µÇÑ »çÀü À¯»ç °Ë»ö °á°ú : 4 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
  • pacemaker
    º¸Á¶ Á¶ÀýÀÚ;ÁöµµÀÚ;ÁÖµ¿ÀÚ;ÆäÀ̽º¸ÞÀÌÄ¿(Àü±âÀÇ ÀÚ±ØÀ¸·Î ½ÉÀåÀÇ ¹Úµ¿À» °è¼Ó½ÃŰ´Â ÀåÄ¡)
  • sequential
    ÀÕµû¶ó ÀϾ´Â
  • indexed sequential data set
    (Àü»ê)»öÀÎ ¼øÂ÷ µ¥ÀÌŸ ¼¼Æ®
  • sequential
    ÀÕ´Þ¾Æ ÀϾ´Â;°á°ú·Î¼­ µû¸£´Â;(ÄÄÇ»ÅÍ)ÃàÂ÷ÀÇ
ÀÌ ¾Æ·¡ ºÎÅÍ´Â °á°ú°¡ ¾ø½À´Ï´Ù.
KMLE ¾àǰ/ÀǾàǰ ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • Á¦Ç°¸í
    ¼ººÐ/ÇÔ·®
    ±¸ºÐ/º¸Çè±Þ¿©
KMLE ¾àǰ/ÀǾàǰ À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • Á¦Ç°¸í
    ¼ººÐ/ÇÔ·®
    ±¸ºÐ/º¸Çè±Þ¿©
¾Ë±â½¬¿î ÀÇÇпë¾îÇ®ÀÌÁý, ¼­¿ïÀÇ´ë ±³¼ö ÁöÁ¦±Ù, °í·ÁÀÇÇÐ ÃâÆÇ ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
´ëÇÑÀÇÇù ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
´ëÇÑÀÇÇù Çʼö ÀÇÇпë¾îÁý »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
¿¾ ´ëÇÑÀÇÇù ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
¿¾ ´ëÇÑÀÇÇù 3 ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
´ëÇÑÇØºÎÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
´ëÇÑÇØºÎÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
´ëÇѽŰæ¿Ü°úÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
    ÇÑÀÚ
´ëÇѽŰæ¿Ü°úÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
    ÇÑÀÚ
´ëÇѱâ»ýÃæÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
´ëÇѱâ»ýÃæÇÐȸ ÀÇÇпë¾î »çÀü °Ë»ö À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
´ëÇÑ»ýÈ­ÇкÐÀÚ»ý¹°ÇÐȸ ¿ë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
KI ÀÇÇпë¾î »çÀü °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
KMLE ÀÇÇоà¾î »çÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
KMLE ÀÚµ¿ÃßÃâ ÀÇÇоà¾î »çÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
ÀÇÇÐ³í¹® ¾àÀÚ(Pubmed/Entrez) °Ë»ö ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
Çѱ¹Ç¥ÁØÁúº´»çÀκзù ¾àÀÚ ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ÄÚµå
    ¿µ¹®
    ÇѱÛ
Çѱ¹Ç¥ÁØÁúº´»çÀκзù ¾àÀÚ À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ÄÚµå
    ¿µ¹®
    ÇѱÛ
°æºÏ´ë Ä¡°ú´ëÇÐ ±¸°­³»°ú ±³½Ç »çÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
    ¼³¸í
CancerWEB ¿µ¿µ ÀÇÇлçÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
MeSH(Medical Subject Headings) ¸ÂÃã °Ë»ö (http://www.nlm.nih.gov) °á°ú : 0 ÆäÀÌÁö: 1
MeSH(Medical Subject Headings) À¯»ç °Ë»ö (http://www.nlm.nih.gov) °á°ú : 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - Merriam-Webster's ÀÇÇлçÀü ¸ÂÃã °Ë»ö (https://www.merriam-webster.com) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - Merriam-Webster's ÀÇÇлçÀü À¯»ç °Ë»ö (https://www.merriam-webster.com) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - A.D.A.M. Medical Encyclopedia ¸ÂÃã °Ë»ö (http://www.nlm.nih.gov) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - A.D.A.M. Medical Encyclopedia À¯»ç °Ë»ö (http://www.nlm.nih.gov) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - MedlinePlus Health Topics ¸ÂÃã °Ë»ö (http://www.nlm.nih.gov) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - MedlinePlus Health Topics À¯»ç °Ë»ö (http://www.nlm.nih.gov) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - µå·¯±×ÀÎÆ÷ ¾àÇÐ Á¤º¸ ¸ÂÃã °Ë»ö (http://www.druginfo.co.kr) °á°ú: 0 ÆäÀÌÁö: 1
Á¦Ç°¸í
ÆÇ¸Å»ç
º¸ÇèÄÚµå ¼ººÐ/ÇÔ·®
±¸ºÐ/º¸Çè±Þ¿©
¿ÜºÎ ¸µÅ© - µå·¯±×ÀÎÆ÷ ¾àÇÐ Á¤º¸ À¯»ç °Ë»ö (http://www.druginfo.co.kr) °á°ú: 0 ÆäÀÌÁö: 1
Á¦Ç°¸í
ÆÇ¸Å»ç
º¸ÇèÄÚµå ¼ººÐ/ÇÔ·®
±¸ºÐ/º¸Çè±Þ¿©
¿ÜºÎ ¸µÅ© - WebMD.com Drug Reference ¸ÂÃã °Ë»ö (http://www.webmd.com) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - WebMD.com Drug Reference À¯»ç °Ë»ö (http://www.webmd.com) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - Drug.com Drugs by Medical Condition ¸ÂÃã °Ë»ö (http://www.drugs.com) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - Drug.com Drugs by Medical Condition À¯»ç °Ë»ö (http://www.drugs.com) °á°ú: 0 ÆäÀÌÁö: 1
KMLE À¥ ¿ë¾î ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
KMLE À¥ ¿ë¾î À¯»ç °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
ÇÑ¿µ/¿µÇÑ »çÀü ¸ÂÃã °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
  • ¿µ¹®
    ÇѱÛ
WordNet ÀÏ¹Ý ¿µ¿µ »çÀü °Ë»ö °á°ú : 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - American Heritage Dictionary ¿µ¿µ»çÀü ¸ÂÃã °Ë»ö (https://www.ahdictionary.com) °á°ú: 0 ÆäÀÌÁö: 1
¿ÜºÎ ¸µÅ© - American Heritage Dictionary ¿µ¿µ»çÀü À¯»ç °Ë»ö (https://www.ahdictionary.com) °á°ú: 0 ÆäÀÌÁö: 1
ÅëÇÕ°Ë»ö ¿Ï·á